User Manual Vesala SG33 X2.0 ENG
30 (32)
Problem
Possible explanations
Remedy
Inductive
coupler or
clamp-on
transformer
does not
work
properly.
Inductive coupler or clamp-on
transformer is positioned too close
to an unconnected cable end.
Position inductive coupler or clamp-
on transformer further from the cable
end.
Ground the unconnected cable end.
Clamp-on transformer is not
completely closed.
Use a larger size clamp-on transformer
to allow it to close on a located cable.
Inductive coupler is misaligned.
Align inductive coupler perpendicular
(at a 90° angle) to the located cable.
Distance between inductive
coupler and located object is too
high.
Inductive couplers have limited range.
Locate inductive coupler closer to the
located object.
Inductive coupler or clamp-on
transformer connected to SG33
has been damaged or failed.
Handle fragile inductive couplers and
clamp-on transformers with care.
Replace the damaged accessory.