IMPORTANT

Before attempting to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes after electrical disconnection before
attempting access. This will allow any moving parts to come to a rest.

Fan
Terminals

Mark centre holes on
mounting surface then
drill out

Remove cover from
POLO fan

VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: [email protected] web: www.ves.co.uk

Original Instructions : Installation, Operation & Maintenance Manual

Original Instructions : Installation, Operation & Maintenance Manual

Original Instructions : Installation, Operation & Maintenance Manual

WEEE Directive

At the end of their useful life the packaging and product should
be disposed of via a suitable recycling centre. Do not dispose of
with normal household waste. Do not burn.

Standards

All POLO fans conform to all relevant British and European
standards and directives. Further information is available
from VES Andover Ltd on request

Please ensure that this document is passed on to the end user

We reserve the right to alter the specification without notice
©VES Andover Ltd. 2009. No part of this publication may be
photocopied or otherwise reproduced without the prior
permission in writing of VES Andover Ltd.

Wire the fan as per
wiring diagram &
instructions

Prepare hole in
mounting surface &
plug mounting holes as
required

Replace front cover

Installation

continued

Wiring Diagrams

Secure fan backing
plate to mounting
surface

Standard, /AS
(Typical Installation)

/PC, /PIR/AT, /AS/PIR/AT
(Typical Installation)

/AT, /HM/AT, /AS/AT, /AS/HM/AT
(Typical Installation)

Maintenance

1. Before cleaning, isolate the fan completely from the mains supply.
2. Carefully remove the front cover
3. To clean the front cover, either wipe it with a damp, lint free cloth or

wash it in warm soapy water. Thoroughly dry the front cover and refit.

4. Do not immerse the fan in water or other liquids to clean any other parts

of the fan.

5. Never use strong solvents to clean the fan.
6. Apart from cleaning, no other maintenance is required.
For replacement fans or install kits please visit

www.vesdirect.co.uk

Specification

Power Supply

230V 50Hz

Operating Temperature

0~40°C

Insulation Class

Double insulated

Motor Protection

IPX4

Motor Type

Ball bearing

Speed (rpm)

2650

Power (W) (POLO100/150)

15/25

Current (A) (POLO100/150)

0.1/0.15

(HM/AT & AS/HM/AT  IPX2 only)

+

-

AT model

2-23

mins

run-on

-

+

- +

- +

Movement

sensitivity

2-23 mins
run-on

PIR model

-

+

+

-

PCB

PCB

PCB

-

+

+

-

HM model

Humidistat

+

-

+

-

2-23 mins
run-on

IMPORTANT

The fan must be fused at 3A unless it forms part of a 5A lighting circuit.
An isolator should be installed to isolate all poles to the fan.

IMPORTANT

All electrical work should be carried out by a qualified engineer and in
accordance with the current IEE Regulations

Warranty

The fan is guaranteed against defects for 1 year from the date of purchase.
If you have any problems, contact VES at the address shown below.

Fan
Terminals

(Light optional)

(Light optional)

Fuse

Fuse

Fuse

Remote/
Light Switch

Remote/
Light Switch

Double Pole

Isolating Switch

Double Pole

Isolating Switch

Double Pole

Isolating Switch

L

L

L

L

T

L

L

N

N

N

N

N

N

Fan
Terminals

Reviews: