HD-98 Door Operator with OST
Door Setup
Printed in USA November, 2011
21
Door Adjustment Diagrams
Figure 9 - Door Opening and Door Closing Adjustments
E06 (Manual
Open Speed)
Range = 1-70
Doors Open (DOL)
E10 (Open Backlash Time)
Range = 1-100
E09 (Open Backlash Speed)
Range = 0-70
E07 (Open Accel Rate)
Range = 1-10
E05 (Open
Sldn Decel Rate)
Range = 1-33
E04 (Open High Speed)
Range = 1-127
E11 (Smooth Turnaround)
Range = 1-100
Doors Closed (DCL)
S
p
eed
Doors Opening
E08 (Open Slowdown Distance)
Range = 0-2000
E19 (High Speed Clamp)
Range = 0-100
(increments of 8, avoid setting over 50)
(setting must be at least 8 more than E04)
3
/
4
Manual Closing Speed
Doors Closed (DCL)
Doors Open (DOL)
E18 (Close Travel- In Distance)
Range = 0-255
E14 (Manual Closing Speed)
Range = 1-70
E15 (Close Accel Rate)
Range = 1-8
E12 (Close High Speed)
Range = 1-127
E13 (Close Sldn Decel Rate)
Range = 1-33
3
/
4
Manual
Closing Speed
E17 (Closing Reduced Torque on Stall)
Range = 0-1
Doors Closing
S
p
eed
E16 (Close Sldn Distance)
Range = 0-2000
E20 (Closing Door Torque)
Range = 1-255
E21 (Nudging Duty)
Range = 1-60