Chapter 3: Installation (Top of Floor)
Route/Attach Instrument Cable
(2/01)
3-3
Route/Attach
Instrument Cable
1.
Remove the junction box access plate from the platform.
2.
A loose coil of instrument cable is located inside the platform channel on either side
of the junction box assembly.
3.
Thread the instrument cable through the hole provided in the scale frame and
platform, continuing through the inside of the platform channel and stopping at the
junction box (see Figure 3-3).
Figure 3-3: Instrument Cable Access Locations
Scale Platform
Frame
Instrument Cable Access Hole
(Typical two holes per corner)
Conduit
Quick-Pit Frame
Top of Floor
Ramp
Top of Floor
Frame
Alternate instrument cable
access hole in ramp application
Ramp Attachment Hole
Scale Platform
Instrument Cable Access Hole
(Typical two holes per corner)
VERTEX Scale (without ramp)
Frame
Ramp Attachment Hole
Top of Floor
Instrument Cable
VERTEX Scale (with ramp)
1.5" (500 lb to 5K)
2" (10K to 20K)