Form: Man10G107 Rev. –C-
02-06-2012
9
V. Machine Setup and Operation
At this point you should have your machine located on a solid bench or work surface. The
Leveling Feet should be installed and the Drive Plate, Clamp Plate Washers & Knobs in place.
There are only a few steps involved in setting up your new machine. After you have used it a
few times, you may develop your own routine, however we suggest you start as described
below.
Steps:
1) Level your machine by centering the bubble in the circle on the round level mounted in the
table of your machine. This is for reference only. The Table Top does not have to be
perfectly level to prevent cartridge cases from tipping while indexing.
2) Referring to the picture above of the Operator Panel that is mounted on the left side of your
machine, please plug the Power Supply into your wall outlet and the other end into the
bottom right of the Operator Panel.
3) Turn the machine on by toggling the ‘On/Off’ switch to the “I” position. You should hear the
fan inside come on and the green power indicator light should shine bright.
4) Rotate the ‘Timer Control Knob’ counter-clockwise to its minimum setting of approximately
1.5 seconds as shown in the picture.