The electronic water leak detection system is installed in the rear left
had corner of the cooler. If a water leak should occur inside the cooler and wa-
ter collects in the leak probe tray the power will automatically be shut off.
When power is cut off due to water leak:
a. Un-plug the cooler and remove the left side panel by removing the 2
screws and sliding the panel back .
b. Remove any excess water in the bottom, lift and wipe the detection
probes dry. Replace all removed components.
c. Re-connect power to reset the leak controller in the unit and check for
leaks.
Figure 9A
Leak Detector Electronic probe location
Slide panel
backward to
remove
13
7.1 Electronic Leak Detection system
Figure 4b.
Installation Precautions
Do not place cooler next to
oven or dishwasher. Keep
out of direct sunlight.
Be sure to use correct power
voltage. Plug power cord
directly into electrical socket.
4.2 Cooler Water Connections
When received, the water connections on the back have color coded
tube sections with red shipping caps on them. These tube sections must be
removed before making water connections. To remove the tube sections see
Figure 7. The 1/4” plastic tubing should be used for making the Feed Water. If
hard copper tubing is used for the Feed Water and Drain connections, the bulk-
head fittings must be changed to a metal fitting.
4.3 Feed Water Connections
To connect the feed water, used the supplied self-piercing saddle
valve to connect to the cold water supply line under the sink. Attach the 1/4”
tubing to the compression fitting on the side of the valve. Clamp the saddle
valve over the copper or plastic feed line (cold water only). Turn the handle on
the valve until the needle stem pierces the tube. Then retract the needle 1-2
turns to start water flow. See Figure 5.
6
Summary of Contents for PureWaterCooler PureChill PWC-900
Page 2: ......
Page 22: ......
Page 23: ......