Introduction
EBX-18 Hardware Reference Manual
5
E
ARTH
G
ROUND
R
EQUIREMENT
All mounting standoffs should be connected to earth ground (chassis ground). This provides
proper grounding for EMI purposes. Figure 2 shows the locations of the board’s mounting holes.
All eight mounting holes identified in Figure 2 must be connected to earth ground.
Figure 2. Attaching the EBX-18 to Earth Ground