LIGHTING GAS BURNERS FITTED WITH FLAME FAILURE
SAFETY DEVICE (Semi-rapid and Triple ring burners)
In order to light the burner, you must:
1. Push and turn the knob in an anti-clockwise direction up to the
position
(maximum rate), push in and hold the knob until the flame has been lit (fig. 2.2).
The sparks produced by the lighter situated inside the relative burner will light the
flame.
In the event that the local gas supply conditions makes it difficult to light the burner in
position (maximum rate), try again with the knob in
position (minimum rate).
2. Wait for about ten seconds after the gas burner has been lit before letting go the
knob (safety device activation delay).
3. Adjust the gas valve to the desired position.
If there is no mains electrical supply, the burners can be used with no restriction.
In that case, in order to light the burner, you must:
1. Bring a lighted match close to the burner (as per side figure) and keep it in place until
the burner has been ignited.
2. Push and turn the knob in an anti-clockwise direction up to the
position
(maximum rate), push in and hold the knob until the flame has been lit (fig. 2.2).
In the event that the local gas supply conditions makes it difficult to light the burner in
position (maximum rate), try again with the knob in
position (minimum rate).
3. Wait for about ten seconds after the gas burner has been lit before letting go the
knob (safety device activation delay).
4. Adjust the gas valve to the desired position.
If the burner flame should go out for some reason, the safety valve will automatically stop
the gas flow.
To re-light the burner, return the knob to the closed
position,
wait for at least 1
minute
and then repeat the lighting procedure.
If your local gas supply makes it difficult to light the burner with the knob set to maximum,
set the knob to minimum and repeat the operation.