WDV See-thru Gas Fireplace
SECURE THE FIREPLACE
The fireplace must be secured to the floor and/or to framing
studs as shown in
Figure 6.
Use two (2) wood screws or
masonry/ concrete screws to secure fireplace to the floor.
Use four (4) screws to attach fireplace to framing. The side
nailing flanges are
1
⁄
2
" or
5
⁄
8
" to accommodate different wall
thickness.
PRE-INSTALLATION INFORMATION
NOTE
Never install combustible materials over
front face of fireplace.
FINISHING MATERIAL
NOTE
: Any remote wiring (i.e. remote control, wall switch,
and optional fan) must be done prior to final finishing to
avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel,
or other materials with a UL fire rating of Zero) may be
used to cover the black painted face of the appliance. It is
permissible to bring combustible wall board to the top of
the standoffs on the top and to the wall board stand-offs
on the sides of the unit. A 300°F minimum adhesive may
be used to attach facing materials to the black surface. If
joints between the finished wall and the fireplace surround
are sealed, a 300°F minimum sealant material (General
Electric RTV103 or equivalent) must be used.
NOTE:
Fireplace may be installed on top of framing or
platform constructed of combustible materials which do
not protrude beyond the face.
FP2747
secure fireplace
6”
Framing Members
Nailing Flange
FP2747
Figure 6 -
Secure Fireplace to Framing Studs
Nailing Flange
Nailing Flange
Screws
Screws
Noncombustible Material