background image

4

Vermont Castings Radiance

1. Install only in accordance with National Fuel Gas

Code, ANSI Z223.1 - latest edition. (Exception:
Do not derate this appliance for altitude. This
appliance has been tested and listed for use in
altitudes up to 10,000 feet. Maintain the manifold
pressure at 3.5 inches W.C. for Natural Gas and
11 inches W.C. for LP gas.)

2. Use only the installation instructions provided

by the manufacturer for this appliance. Installa-
tion and repair should be done by a qualified
service person. The appliance should be in-
spected before use and at least annually by a
professional service person. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is
imperative that control compartments, burners
and circulating air passageways of the appliance
be kept clean.

3. WARNING: Any change to this heater or its

controls can be dangerous. DO NOT make
modifications to any heater or associated parts.

4. DO NOT install this heater in a bedroom or bath-

room.

5. Due to high surface temperatures, DO NOT

install this heater

in a recreation vehicle,

where curtains, furniture, clothing, or
other flammable objects are less than 36
inches from the front, top, or sides of the
heater,

in high traffic areas,

in windy or drafty areas.

6. DO NOT place clothing or other flammable

material on or near the appliance.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide

to safe and proper operation of this heater.

7. This heater needs fresh, outside air ventilation to

operate properly. See Fresh Air Requirements on
pages 6 and 7.

8. If heater shuts off, heater may not have enough fresh

air ventilation. Provide more fresh air. If heater keeps
shutting off, see Troubleshooting, page 17.

9. DO NOT operate this heater

where flammable liquids or vapors are used
or stored

under dusty conditions.

10. The heater becomes very hot when operating.

Alert children and adults to stay away from hot
surfaces to avoid burns or clothing ignition. The
heater will remain hot for a time after shut-down.
Allow surface to cool before touching.

11. Carefully supervise young children when they

are in the room with the heater.

12. Do not use the heater if any part has been

exposed to or under water. Immediately call a
qualified service technician to inspect the room
heater and to replace any part of the control
system and any gas control which has been
under water.

13. DO NOT operate the heater if any log is broken

or damaged.

14. Turn heater off and let cool before servicing.

Only a qualified service person should service
and repair heater.

15. If so equipped, DO NOT operate this appliance

with the optional glass panel removed. If the
glass panel is removed from the appliance for
service or cleaning, it must be replaced before
operating the heater.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches,
dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once!
Have the heater serviced. Some people are more affected by carbon monoxide than others. These include
pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those
at high altitudes.

DANGER

CARBON MONOXIDE POISONING MAY LEAD TO DEATH!

Safety Information

Warnings

IMPORTANT: Read this  owner's manual carefully and completely before trying to assemble,
operate, or service this heater. Improper use of this heater can cause serious injury or death from
burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

Summary of Contents for Radiance RUVS40

Page 1: ...mbustion and ventilation air must be provided Radiance Vent Free Gas Heater Model RUVS40 3000 0456c 1000 INSTALLER CONSUMER SAFETY INFORMATION WARNING If the information in this manual is not followed...

Page 2: ...ontact your hearth products dealer or local gas supplier for the name of a qualified service person INSTALLER Please read this manual carefully before you begin the installation procedures Failure to...

Page 3: ...ket manufactured mobile home where not prohibited by state or local codes This appliance is to be used only with the type of gas specified on the rating plate which is attached to the rear panel This...

Page 4: ...ore fresh air If heater keeps shutting off see Troubleshooting page 17 9 DO NOT operate this heater where flammable liquids or vapors are used or stored under dusty conditions 10 The heater becomes ve...

Page 5: ...gas flow to the burner in the event that sufficient fresh air becomes unavailable for continued safe operation Quick Installation Your Radiance Vent Free heater is shipped completely assembled and re...

Page 6: ...caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing elec...

Page 7: ...f the two grilles must provide an opening of at least 50 square inches with all opening dimensions being at least 3 One grille must be located within 12 of the ceiling the other within 12 of the floor...

Page 8: ...air currents These currents move heat to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacc...

Page 9: ...the help of an assistant carefully remove the stove from the pallet and move it close to its final installed position Lift the stove by the sides Do not lift by any part of the stove front Hardware Ba...

Page 10: ...shroud to the side of the stove Remove the sheet metal screw C that fastens the switchbox to the rear shroud Remove the two sheet metal screws D that secure the inner and outer shroud together Let th...

Page 11: ...snapstat Fig 13 Looking through the stove front locate the snapstat mounting screws on the side of the left air duct under the top plate Remove the front screw A but only loosen the rear screw Slip t...

Page 12: ...ness These wires are accessible from under the left rear side of the stove Either thermostat wire may connected to either terminal Fig 16 3 Place the control switch on the rear of the stove in the T S...

Page 13: ...the rear There should be a gap of about 13 16 between the front of the burner and the inside front wall of the firebox Place the two front ember log sections 4 and 5 Fig 21 in the slot at the front o...

Page 14: ...orners engage notches at the top forward corners of the stove sides Then gently swing the bottom of the front panel to a vertical position and lower it till prongs on its bottom left and right corners...

Page 15: ...h new logs paint and metal being heated Odors should dissipate within a few hours or so however you can open a window to provide plenty of fresh air to alleviate this condition Pilot and Burner Inspec...

Page 16: ...ESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE TO TURN OFF GAS TO APPLIANCE A This appliance has a pilot When lighting the pilot follow...

Page 17: ...is can be caused by a Incorrect gas pressure and or b other conditions that should be identified only by a qualified service technician 7 Thermocouple is damaged 8 Control Valve is damaged Solution 1...

Page 18: ...ion NG 5 W C 8 W C 5 W C 7 W C at elevations over 8000 ft LP 11 W C 12 W C Warning If you smell gas Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use...

Page 19: ...DO NOT OPERATE THE HEATER WITH A DAMAGED OR LOOSE LOG SET Use a soft bristled brush vacuum cleaner attach ment to remove dust or debris from the log set pilot and burner Use care as the log set is fr...

Page 20: ...slowly pour it into the water mixing thoroughly 4 Place the combustor into the solution and allow to soak for fifteen 15 minutes If the module is not completely covered follow steps 1 3 to prepare en...

Page 21: ...ake changes in design materials specifications prices and discontinue colors and products at any time without notice 0456 1 Grille 1301192 2 Grille Screen 1601933 3 Top 1301186 4 End Left 1301234 5 En...

Page 22: ...1229 47 Cable Control Door 1601924 48 Spring Control Door 1201842 49 Control Door 1301220 50 Control Door Handle Wood 1600660 Handle Stub 1601981 51 Damper Tab 8 1601488 52 1 4 20 x 3 8 Phillips Screw...

Page 23: ...pection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer for parts and or labor Any Radiance Natural Vent Room Heater or part thereof tha...

Page 24: ...s Radiance The Vermont Castings Majestic Products Company 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7885 www majesticproducts com www vermontcastings com The Vermont Castings Majesti...