background image

2

20004180

Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam-
age.  Read these directions thoroughly before installation.  For assistance or additional information, 
consult your gas log dealer, qualified installer, service agency or 
gas supplier.

Young children are not allowed to operate this unit and must be supervised when they are in the same 
area as the appliance.

If not installed, operated, and maintained in accordance with the manufacturer’s instructions, this prod-
uct could expose you to substances in fuel or fuel combustion which are known to the State of California 
to cause cancer, birth defects, or other reproductive harm.

Fireplace damper 

MUST

 be locked fully open when operating the gas log set.  

If the fireplace has glass doors, 

operate gas log set only with doors fully opened

.  The fireplace 

screen must be in place when the appliance is operating and, unless other provisions for combustion 
air are provided, the screen shall have an opening(s) for introduction of combustion air.
The log set and its individual shut-off valve 

MUST

 be isolated from the gas supply piping system by 

closing its individual shut-off valve during any pressure testing of gas supply at test pressures equal to 
or less than 1/2 psig.
The log set and its individual shut-off valve 

MUST

 be disconnected from the gas supply piping system 

during any pressure testing of that system at test pressures in excess of 1/2 psig.
Keep the gas log set clear and free from combustible materials, gasoline and other flammable vapors 
and liquids.
If the log set is to be installed in a fireplace other than the Vermont Castings ODSHR42 fireplace, the 
minimal firebox dimensions and stainless steel grate must be used. Refer to Page 12 for Optional Ac-
cessories.

WARNING

WARNING

WARNING

INSTALLATION PRECAUTIONS

Proposition 65 Warning:

 Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known 
to the State of California to cause cancer, birth de-
fects and other reproductive harm.
California Health & Safety Code Sec. 25249.6

Summary of Contents for OD30CFLN/P

Page 1: ... COMPANY EXPE RIENCED IN THE INSTALLATION REPAIR AND SERVICING OF THIS TYPE OF GAS APPLIANCE DO NOT MODIFY ALTER OR TAMPER WITH ANY PART OF THIS HEATER CONTROL OR LOGS INSTALLER PLEASE NOTE DO NOT BEGIN INSTALLATION OF THIS GAS LOGSET UNTIL ALL INSTRUCTIONS HAVE BEEN READ AND UNDERSTOOD Certified as CSA 7 94 U S manually lighted decorative gas appliance for installation in solid fuel burning firepla...

Page 2: ... air are provided the screen shall have an opening s for introduction of combustion air The log set and its individual shut off valve MUST be isolated from the gas supply piping system by closing its individual shut off valve during any pressure testing of gas supply at test pressures equal to or less than 1 2 psig The log set and its individual shut off valve MUST be disconnected from the gas sup...

Page 3: ...ct you in the event of an explosion WARNING If the fireplace contains glass doors they must remain open at all times during the opera tion of the logset allowing combustion air to circulate In order to avoid any possible gas leaks apply pipe joint compound to all non flared threaded connections involved in this installation For propane the joint compound must be resistant to the corrosive action of ...

Page 4: ... Supply Set Input Width Flue Pressure Size Btu hr Back Front Depth Height Size Minimum Maximum 30 90 000 27 36 18 18 79 sq in 3 5 w c 7 0 w c Minimum Clearances Specifications Natural Gas Units Propane Gas Units Gas Log Minimum Firebox Dimensions Minimum Gas Supply Set Input Width Flue Pressure Size Btu hr Back Front Depth Height Size Minimum Maximum 30 60 000 27 36 18 18 79 sq in 11 0 w c 14 0 w c...

Page 5: ...or burner connection purposes only Ex act burner placement will be covered on Page 7 after all connections have been made 3 Attach the Gas Supply Fitting onto your fireplace s gas supply pipe as shown in Figure 2 4 Attach one end of the Flexible Gas Connector to the brass Burner Inlet Fitting which has been factory installed into the burner 5 Attach the other end of the Gas Connector to the flared s...

Page 6: ...ng the bolt provided to the damper plate with an adjustable wrench Fig 5 If the Damper Stop does not fit drill a 1 4 hole into the damper plate and install an anchor bolt with nut at a 90 degree angle so that the damper plate will remain fully open The proper finished installation of the Damper Stop is shown in Figure 6 If the bolt fails to block the damper in an open position the damper should be r...

Page 7: ...y across burner covering lava rock Fig 9 3 Slide the mesh screen under the grate but on top of glowing embers so the mesh piece covers the burner pan material Fig 10 4 Open remaining bag of embers and place evenly on top of mesh screen Fig 10 5 Spread lava rock onto fireplace hearth around the burner pan for decorative purposes Fig 11 FP1146 OD30 embers 8 13 01 djt Glowing Embers FP1146 Fig 9 Ember...

Page 8: ...one side of the cover on the front edge of the hearth brick just behind the ash lip Fig 14 inside the screens Allow the back edge of the cover to rest against the back and side brick covering the log set 2 Place the second half of the cover in the same manner overlapping the first half Fig 15 CAUTION Be sure to remove cover before lighting gas log set KT260 ODLSSC side view KT260 Fig 14 ODLSSC inst...

Page 9: ...in which the log set is installed Appliance Break in During the 2 3 hour appliance break in period you may detect an odor from the appliance as the various water based paints used in the manufacture of this log set cure This is a normal and temporary situation that is not a cause for alarm To ensure proper curing of the logs 1 Ignite a 2 flame and maintain it for 1 2 hour 2 Burn the logs in consecu...

Page 10: ...nstalled the correct orifice into the set Burner Is Excessively Noisy Please note The movement and combustion of gas will create low unavoidable levels of noise Excessive gas pressure Make sure the gas pressure coming into the fireplace does not exceed the maximum pressure allowed with this gas set refer to tables on page 4 If you are using the gas logs with a safety pilot kit make sure you installe...

Page 11: ...1c Center Left Cross Log NEO 2 4312847 1d Center Right Cross Log NNO 3 4312848 1e Outside Right Cross Log NNS 3 4312779 1f Back Log NNS30B 4312814 1g Front Left Log KO 30L 4312857 1h Front Right Log KO 24L 4312844 2 Bag of Glowing Embers 4310001 3 Bag of Lava Rock 3310041 4 Grate Step 20004202 5 Damper Stop 20002575 6 Burner Tube 3 8 20003828 7 Pan Assembly 20004179 8 Orifice Natural Gas 20000961 9...

Page 12: ... Regulator Propane 3304191 16 Orifice Propane 20001280 17 Orifice Holder Propane 20000012 18 Air Mixer Shutter 20000013 19 Air Shutter Screen 20004686 Optional Accessories Item Description Part Number Grate Stainless Steel For use in fireplaces other than the ODSHR42 20002230 ...

Page 13: ...13 20004180 ...

Page 14: ...14 20004180 ...

Page 15: ...nties specified in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components referred to in those para graphs subject to the following conditions and limitations 1 These warranties are extended only to the Gas Ap pliance installed in the continental United States including Alas...

Page 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products ...