47
10002428
Vermont Castings, Majestic Products DVRT36/ 39/ 43
8. Remove the compression fitting which holds the
aluminium tubing in the pilot assembly. This will
reveal the pilot orifice which must be replaced with
the one provided in the conversion kit.
9a. Units with SIT valve (see pictures in the
installation instructions supplied with the kit):
a) Using a Torx T20 or slotted screwdriver, remove
and save the three pressure regulator mounting
screws (A), pressure regulator tower (B) and
diaphragm (C).
b) Ensure the rubber gasket (D) is properly
positioned and install the new Hi/ Lo pressure
regulator to the valve using the new screws (E)
supplied with the kit. Tighten screws securely.
(Ref. torque: 25 in-lb).
c) Install the enclosed identification label (F) to the
valve body where it can be easily seen.
9b.Units with Honeywell valve:
The Honeywell valve fitted to this unit is preset for
LP gas. It is convertible to natural gas by the
installation of a color coded “conversion screw.” To
insert the conversion screw, refer to the instructions
and diagrams in the Honeywell Installation
Instructions supplied in the conversion kit packaged
with the DVRT36RMH unit.
10. Reassemble the fireplace in the reverse order,
except for the window frame assembly. Leave this
off until the unit has been checked for leaks and the
gas supply line has been bled.
11. After bleeding the gas line and checking for leaks
with a soap solution, replace the window frame
assembly. Fire up the unit, check for flame
impingement on the logs, adjusting them if
necessary. Check the manifold and supply
pressures.
NOTE: If further assistance is required, refer to
‘Troubleshooting’ and ‘Parts List’ in this manual.