14
26D3310
LOCATION OF FIREPLACE
Carefully select the best location for installation of your unvented fi replace. The following factors should be taken
into consideration.
• Clearance to side wall, ceiling, woodwork and window or other combustibles. Refer to “Clearances and Height
Requirements” section on page 15. Minimum clearances to combustibles
must be maintained.
• Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air registers for forced
air furnaces / air conditioners, windows or doors.
• Installation must provide adequate ventilation and combustion air.
• DO NOT INSTALL THIS MODEL IN A BEDROOM OR BATHROOM.
• Location should be out of high traffi c areas and away from furniture and draperies due to heat from fi rebox.
• Never obstruct the front opening of the unvented fi replace or restrict the fl ow of combustion and ventilation air.
• Minimize modifi cations to existing construction.
See Figure 8
below for location suggestions.
• Do not install in the vicinity where gasoline or other fl ammable liquids may be stored. The unvented fi rebox must be
kept clear and free from the combustible materials.