28
26D3310
OPERATING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions”, page 29.
4. Turn gas control knob clockwise
to the OFF position, set the thermostat to the lowest setting
and turn ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell gas, STOP!
Follow “What to Do if You Smell Gas”, page 25. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise
to IGN position. Push
in control knob for 5 seconds.
NOTE: If you are running the heater for the fi rst time, it
will be necessary to press in the control knob for 30 seconds to allow air to bleed
out of the gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 10 seconds to prevent the fl ame detector from shutting
off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to
ON position or adjust thermostat to desired setting.
11. If the gas logs will not operate, follow the instructions “To Turn Off Gas To Heater” below and call
your service technician or gas supplier.
TO TURN OFF GAS TO HEATER
1. Turn control knob clockwise
to OFF position to completely shut off the heater.
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
Figure 35 - Pilot
Figure 36 - Control Cover Plate for Milli-Volt
Hi/Lo Control
Ignitor Pilot Control
On/Off Switch
Piezo
Hi/Lo Control
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
MILLI-VOLT/THERMOSTAT CONTROL
LIGHTING INSTRUCTIONS
Summary of Contents for DFS3224A
Page 38: ...38 26D3310 NOTES...
Page 39: ...26D3310 39 NOTES...