45
20306747
DVM Series Direct Vent Gas Fireplace
CLEANING AND MAINTENANCE
VENT SYSTEM
The fireplace and venting system should be inspected
before initial use and at least annually by a qualified field
service person. Inspect the external vent cap on a regular
basis to make sure that no debris is interfering with the
airflow. Inspect entire venting system to ensure proper
function.
GLASS DOOR
Thoroughly clean the inside of the glass door after using
the fireplace for ten hours. Periodically clean the glass
door as necessary.
When cleaning the glass, remember:
•
Do not remove the glass when hot.
Allow glass to
cool before removal.
•
NEVER use abrasive materials.
•
Keep children and pets a safe distance away.
•
Never operate the fireplace without the glass door
properly secured.
•
Never operate the fireplace if the glass is broken.
•
Replace any glass that is chipped, cracked, or broken.
Replacement glass door assemblies MUST be supplied
by the fireplace manufacturer –
No substitute materi
-
als may be used.
•
Handle glass door with care to avoid striking or scratch-
ing it on hard objects.
To clean glass door, follow “Glass Removal” procedure
outlined in the
Canopy Installation and Glass Removal
section. Film deposit on the inside of the glass should be
cleaned off using a nontoxic, non-corrosive, non-abrasive,
mild cleaning solution. Simply apply an adequate amount
to the glass and wipe off with a damp cloth. After all main-
tenance has been completed, re-install glass door and
safety screen barrier.
LOGS
Leave logs installed in the fireplace for cleaning. Vacuum
surface of the logs with a brush attachment. If logs must
be removed for cleaning, handle carefully by holding gently
at each end. Gloves are recommended to prevent skin irri-
tation from ceramic fibers. If skin becomes irritated, wash
gently with soap and water. Vacuum surface of logs with
brush attachment or brush logs with a soft bristle brush (i.e.
clean, dry paintbrush). To place logs back in the fireplace,
see the
Log and Rock Wool Installation
.
NOTE:
Do not use cleaning fluid to clean logs.
ROCK WOOL
Replace or add rock wool as required following installation
instructions in the
Log and Rock Wool Installation
section