CFDV Series Direct Vent Gas Fireplace

Installation and Operating Instructions

Models: 33CFDV(N/P)(V/I)SL, 36CFDV(N/P)(V/I)SL, 42CFDV(N/P)(V/I)SL

20306739  1115  Rev. 2

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for  

future reference.

•  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

•  WHAT TO DO IF YOU SMELL GAS

  – Do not try to light any appliance.

  – Do not touch any electrical switch; do 

not use any phone in your building.

  – Leave the building immediately.

  – Immediately call your gas supplier from 

a neighbor's phone. Follow the gas 

supplier's instructions.

  – If you cannot reach your gas supplier, 

call the fire department.

•  Installation and service must be performed 

by a qualified installer, service agency or 

the gas supplier.

WARNING:  Improper  installation,  adjustment, 

alteration, service or maintenance can cause 

injury or property damage. Refer to this manual. 

For assistance or additional information consult 

a  qualified  installer,  service  agency  or  the 

gas supplier.   

This appliance may be installed in an aftermarket,* 

permanently located, manufactured home (USA 

only) or mobile home, where not prohibited by 

local codes.

This appliance is for use only with the type of gas 

indicated on the rating plate. This appliance is 

not convertible for use with other gases, unless 

a certified kit is used. 

*  Aftermarket: Completion of sale, not for purpose of resale, from 

the manufacturer. 

 WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death or 

property damage.

DANGER

HOT GLASS 

WILL

CAUSE BURNS

.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

Un panneau vitré chaud

 peut 

causer des brûlures.

Laissez refroidir le panneau

vitr

é

 avant d’y toucher.

Ne laisser jamais

 les enfants

toucher le panneau vitr

é

.

A barrier designed to reduce the risk of burns from 

the hot viewing glass is provided with this 

appliance and shall be installed.

Une barrière visant à réduire le risque de brûlure 

par le hublot chaude est fournie avec cet 

appareil et doit être installé.

DANGER

CERTIFIED

S

AFETY

 

B

ARRIER

Summary of Contents for 33CFDVNI

Page 1: ...ervice or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Thisappliancema...

Page 2: ...witch 36 Optional DC Remote Systems 36 Optional Fan Blower System BLOT 37 Optional Fan Blower System FK12 37 Operating Instructions Millivolt 38 For Your Safety Read Before Lighting 38 What To Do If Y...

Page 3: ...ed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs the fire place...

Page 4: ...replace any part of the control system and any gas control which has been under water 22 Do not operate fireplace if any log is broken 23 Do not use a blower insert heat exchanger insert or any other...

Page 5: ...ICATIONS ORIFICE SIZE GAS PRESSURES Natural Gas Propane LP Inlet Minimum 5 5 w c 11 0 w c Inlet Maximum 14 0 w c 14 0 w c Manifold Pressure 3 5 w c 10 0 w c COLD CLIMATE OPTION IPI Models Only NOTE If...

Page 6: ...luded Four 4 AA alkaline batteries NOTE To ensure you will always have back up pow er available to your fireplace replace batteries before each heating season Four 4 AA alkaline batteries are required...

Page 7: ...ying with Local Codes Pipe Sealant Approved for use with Propane LPG Resistant to Sulfur Compounds FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place Construc...

Page 8: ...343 4 883 mm D 27 689 mm 291 8 740 mm 331 8 841 mm E 18 457 mm 197 8 505 mm 197 8 505 mm F 157 8 430 mm 157 8 430 mm 157 8 430 mm G 211 8 537 mm 221 8 562 mm 261 2 673 mm H 231 4 591 mm 255 8 657 mm 2...

Page 9: ...ty where gasoline or other flammable liquids may be stored Vent pipe routing See Venting section found in this manual for allowable venting configurations These units can be installed in a bedroom See...

Page 10: ...i e remote control wall switch and optional fan must be done prior to final finishing to avoid costly reconstruction Only noncombustible materials i e brick tile slate steel or other materials with a...

Page 11: ...e Screws 7 Collar FP3022 Figure 12 Remove 7 Collar and Gasket 3 Remove the plate with the 4 collar and gasket by re moving four 4 screws Set aside Figure 13 4 Remove the top plate located on top of th...

Page 12: ...e 16 Remove Small Square Plate and Gasket 8 Install the plate with the 4 collar and gaskets on top of the unit with screws previously removed 9 Install the plate with the 7 collar and gaskets on top o...

Page 13: ...ents or clearance considerations detailed in this manual Venting terminals shall not be recessed into a wall or sid ing Vertical side wall venting in horizontal applications must be installed with a 1...

Page 14: ...U h 30kW 36 91cm for appliances 100 000 BTU h 30kW 6 15cm for appliances 10 000 BTU h 3kW 9 23cm for appliances 10 000 BTU h 3kW and 50 000 BTU h 15kW 12 30cm for appliances 50 000 BTU h 15kW C Cleara...

Page 15: ...mbustible Noncombustible 12 305 mm M Balcony with perpendicular side wall M 12 305 mm P 6 152 mm M F Alcove Applications C D C E V V Combustible Noncombustible E Min 2 51 mm for non vinyl sidewalls Mi...

Page 16: ...flues shall be sealed in this manner unless otherwise stated VENTING INSTALLATION Note The end of the pipe sections with the lances tabs on it will face toward the appliance 1 Align Seams 2 Rotate Fig...

Page 17: ...too long the inner and outer flues of the slip section can be cut to the desired length WARNING Risk of Fire Explosion DO NOT break seals on slip sections Use care when re moving termination cap from...

Page 18: ...25 mm clearance at the sides and bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration If vertical rise is 71 2 feet 2...

Page 19: ...iance or end of the 45 elbow in a corner ap plication and the outside face of the rear wall is 20 508 mm Figure 23 Only one 45 elbow is allowed in these installations Minimum clearances between vent p...

Page 20: ...AP WARNING Risk of Fire The telescoping flue sec tion of the termination cap MUST be used when connecting vent 11 2 38 mm minimum overlap of vent and telescoping flue section is required Failure to ma...

Page 21: ...ent pipes and combus tible materials is 3 76 mm on top and 1 25 mm on the bottom and sides unless otherwise noted When vent termination exits through foundations less than 20 508 mm below siding outcr...

Page 22: ...th of the horizontal run MUST be reduced by 18 457 mm This does not apply if the 45 elbows are installed on the vertical part of the vent system The maximum number of elbow degrees in a system is 270...

Page 23: ...vent vertical through the roof installa tions install the supplied flue restrictors onto the top edge of the firebox flue adapter according to the Vertical Side wall Installation Flue Restrictor Char...

Page 24: ...Figure 43 Vertical Height Requirements X X FP1182 Figure 44 Horizontal Length Requirement to the wall with screws provided and caulk around the wall plate to weatherproof As an alternative to screwin...

Page 25: ...ings should be equally spaced to prevent the inside and outside flex pipe from touching each other and should be placed in locations where the vent must bend 11 Extend 65 8 outside flex pipe to reach...

Page 26: ...tight seal is made around the vent pipe coming through the wall BG401 Snorkel 2 10 99 djt Snorkel Wall Screws Foundation Recess Watertight Seal Around Pipe Sheet Metal Screws BG401 Figure 48 Snorkel i...

Page 27: ...n 8 2 5 m vertical rise is required Two sets of 45 elbow offsets may be used within the vertical sections From 0 to a maximum of 8 2 5 m of vent pipe can be used between elbows Figure 52 SLP HVS suppo...

Page 28: ...starter into the starting collar of the appliance 2 Slide the small gear clamp over the inner flexible vent pipe and push out of the way 3 Pull and extend the inner flexible vent 4 Slide the inner ve...

Page 29: ...floor Figure 55 Frame the area with the same sized lumber as used in ceiling floor joist When installing a top vent vertical termination appliance the hole should be directly above the appliance unles...

Page 30: ...maintain clearance Roof Support 1 Fasten the roof support to the roof sheathing using 2 wood screws provided Figure 58 Ensure that the termination pipe is centered and has a minimum of 1 clearance on...

Page 31: ...rom roof to lowest discharge opening 24 in min 610 mm Roof Pitch H Min Ft Roof Pitch H Min Ft Flat to 6 12 1 0 Over 11 12 to 12 12 4 0 Over 6 12 to 7 12 1 25 Over 12 12 to 14 12 5 0 Over 7 12 to 8 12...

Page 32: ...pipe of the rig id pipe length using three 3 self tapping 10 screws 2 Attach the outer flex adapter to the outer pipe of the rigid pipe lenth using three 3 self tapping 10 screws 3 Attach the 4 and 6...

Page 33: ...r If you do not reduce incoming gas pressure burner system regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 66 Pointing the vent down protects it...

Page 34: ...e LP From External Regulator 11 w c to 13 w c Pressure Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess seal ant in pipe could result in cl...

Page 35: ...0 latest edition and Canadian Electrical Code CSA C22 1 WARNING 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to LO to get minimum pressure 5 To chec...

Page 36: ...ays check with local code Figure 70 Wiring Diagram for Wall Switch ELECTRICAL INSTALLATION MILLIVOLT OPTIONAL DC REMOTE SYSTEMS See section entitled Hearth Mount in the Millivolt hand held remote inst...

Page 37: ...equires that 110 120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed Figure 72 Black Black Green Black Black White Thermostatic Switch Receptacle Ju...

Page 38: ...tempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to repl...

Page 39: ...ess fully and hold pilot gas knob Depress piezo igniter as many times as needed to ignite pilot Keep knob fully depressed for 30 60 seconds Release and check that pilot continues to burn If the pilot...

Page 40: ...to ignite MAIN BURNER SWITCH This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the switch is in the ON position to light the main burner Depr...

Page 41: ...en servicing controls Wiring errors can cause improper and dangerous operation Figure 74 IPI Valve FP3034 IPI gas valve Pressure Inlet Pilot Adjust ment Screw Pressure Outlet Do NOT use open flame to...

Page 42: ...his connector Refer to the wiring diagram in Figure 75 Figure 75 Junction Box Wiring Diagram FP1912 Junction box wiring 8 08 Junction Box Factory Supplied Not Supplied 120V AC 60Hz ELECTRICAL INSTALLA...

Page 43: ...AUTION Electrical connections should only be performedbyaqualified licensedelectrician Main power supply must be turned off before connecting fans to the main electrical power supply or performing ser...

Page 44: ...ctions If you cannot reach your gas supplier call the fire department C Turn Master Switch to ON position by hand Never use tools If the switch will not function by hand do not try to repair it Call a...

Page 45: ...the prior page If you do not smell gas go to next step 4 Press the wall switch to the ON position Sparker will spark and pilot flame will light 5 Once pilot flame is established the main burner flame...

Page 46: ...Red LED Flash 5 times Pilot valve voltage error Red LED Flash 6 times Main valve voltage error Red LED Flash 7 times Low battery Red LED 2 5 sec Flash once REMOTE FUNCTION OPERATION ICON Fireplace On...

Page 47: ...t glass frame aside Figure 78 Remove Safety Barrier and Glass Frame CAUTION Each latch has a quick spring force When reinstalling glass keep fingers clear FP3041 glass frame latch Figure 77 Glass Fram...

Page 48: ...4 Self drilling 8 screws NOTE If logs are being used porcelain panels must be installed first 1 Remove safety barrier glass frame and stones fire glass or logs if applicable 2 Remove top heat shield 3...

Page 49: ...glow Adjust embers as necessary to achieve an even and clean flame KT1893 firebrick Retainer Bracket Left Panel Rear Panel Right Panel KT1893 INSTALLING BRICK LINER KIT Kit contents One 1 Right panel...

Page 50: ...3 Bend the tab in the center front of the false hearth up to a 90 angle Figure 87 Place the top log 4 by resting the square notch located on the bottom of the log over the tab mentioned above Rest the...

Page 51: ...re 88 Center Tab Figure 87 LG1183 Figure 89 LAVA ROCK PLACEMENT Sprinkle lava rock on the raised floor of the inner combus tion chamber Evenly distribute the rock Figure 89 Do not sprinkle the lava ro...

Page 52: ...frame assembly by releasing the latches on top of the fireplaces and tilting frame for ward Lift off and set aside 4 Remove the logs if they are installed Vacuum the rock wool off the burner 5 Remove...

Page 53: ...d or barrier removed for servicing the appliance must be replaced prior to operating the appliance See parts list for model number SAFETY BARRIER INSTALLATION INSTRUCTIONS DANGER HOT GLASS WILL CAUSE...

Page 54: ...eplace manufacturer No substitute materials may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in t...

Page 55: ...eplace pilot assembly B If thermocouple is producing more than 15 mV replace faulty valve 3 Pilot burning valve knob turned to ON switch is turned to ON but burner will not ignite A Defective switch w...

Page 56: ...function Check the cold climate switch and control board Replace cold climate switch Battery polarity wrong Batteries low AC adaptor plugged into junction box Reinstall batteries correctly Change batt...

Page 57: ...Kit Bronze GKB Glass Kit Diamond GKD Glass Kit Onyx GKO Glass Kit Sapphire GKS Blower Kits T Stat Blower w Speed Control BLOT Manual Blower FK12 Speed Control for FK12 26D0746 SYMPTOM POSSIBLE CAUSE A...

Page 58: ...6CFDVSB 42CFDVSB 7 Control Panel Access Door 1 20305572 20307388 20306117 Kits Sold Separately 6 Blower 1 BLOT BLOT BLOT 6 Manual Blower 1 FK12 FK12 FK12 N A Firebrick Kit Cottage Clay 1 FB33CFDVCC FB...

Page 59: ...D0019K 37D0018K 37D0019K 37D0018K 37D0019K 5 Replacement Thermocouple 1 24D0808 24D0808 24D0808 24D0808 24D0808 24D0808 6 Replacement Igniter and Wire 1 10001297 10001297 10001297 10001297 10001297 10...

Page 60: ...Valve Assembly 1 95E0101 95E0102 95E0101 95E0102 95E0101 95E0102 4 Pilot Assembly 1 95E0103 95D0104 95E0103 95E0104 95E0103 95E0104 5 Control Board 1 95E0100 95E0100 95E0100 95E0100 95E0100 95E0100 6...

Page 61: ...tical Vent Termination Kits Vertical termination cap high wind includes storm collar SLP TVHW 0 12 6 12 roof flashing multi pack of 6 SLP RF6M 7 12 12 12 roof flashing multi pack of 6 SLP RF12M 3 12 t...

Page 62: ...irestop 90 elbow 9 12 adjustable termination pipe SLP HVTK Rear vent termination includes adjustable termination cap 1 firestop multi pack of 4 SLP RVTM Horizontal vent termination kit includes adjust...

Page 63: ...OCK SLP PART NO QTY BOX DESCRIPTION SLP DVFAM 4 SLP flex adapter kit w gear clamps multi pack of 4 SLPMP 8 SLP unit and inline pipe adapter to 4 x 7 Twist Lock carton of 8 MBSLP 8 VCG fireplace unit a...

Page 64: ...o comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ONLY 2...

Page 65: ...Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly...

Page 66: ...CFDV Series Gas Fireplace 66 20306739...

Page 67: ...CFDV Series Gas Fireplace 20306739 67...

Page 68: ...al Fireplace Institute NFI comme tant des sp cialistes du NFI en mati red appareils de chauffage au gaz 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com EFFICIENCY RATINGS MODEL E...