CFDV Series Gas Fireplace
56
20306739
TROUBLESHOOTING
IPI SYSTEM
Fli
p the master switch to the ON position.
Press the wall switch to the ON position.
Press the cold climate switch to the ON position.
Check wiring connec
ti
ons
between switch and board
Correct wiring if necessary
Correct wiring if necessary
Ins
pect ignitor wire connection at
board and pilot for damage. Ensure
the ground wire has a solid connection.
Reconnect wire if disconnected.
Replace ignitor wire if damaged.
Check gas supply.
Flame not engul
fi
ng
fl
ame
sensor or pilot
fl
ame too
Adjust sensor pos
iti
on or replace the
pilot.
N
o function
Check the cold climate switch and control board
Replace cold climate switch
Batter
y polarity wrong?
Batt
eries low?
AC adaptor plugged
into junc
ti
on
box?
Reinstall b
atter
ies correctly.
Change
batter
ies.
Plug the AC adaptor in.
Check wiring connec
ti
ons
between valve and board
No beep
No spark at pilot
Pilot doesn’t light
Main burner doesn’t light
No sound from valve
indicating pilot
solenoid open
Adjust sparker posi
ti
on such that the
spark is in the path of the gas
fl
ow or
replace the pilot.
No beep or flashing
green light after
5 seconds.
Make sure control board is
connected to battery pack
wire harness.
Make sure AC adaptor is
plugges into control board.
Make sure Cold Climate switch
is in the OFF position.
Check the spark intensity.
Ensure that the spark wire is
not grounding out.