13
Defiant
®
1975CE Non-Catalytic / Catalytic Woodburning Stove
30005554
ST1180
flue collar heat shield
Sheet
Metal
Screws
Sheet
Metal
Screws
Flue Collar
Heat Shield
ST1180
Fig. 17
Install flue collar heat shield.
Air Deflector
Air Deflector
waRNiNg:
The flue collar heat shield must be installed
in all vertical installations. The flue collar heat shield is
not used when the flue collar is in the rear exit position.
assemble the Removable insert handle
The ceramic removable insert handle opens and closes
the front doors. Remove after each use, and store it in
the handle holder behind the right front leg. Assemble
the handle by passing the 3
³⁄₈
" screw through the ceramic
shaft and into the bright metal nub. (Fig. 19) Tighten care-
fully until snug.
ST540
Assembly
handle
11/00
ST540
Fig. 19
Assemble the front door handle.
ST635
Encore
Install thermostat
handle
2/01
ST635
Fig. 18
Attach the thermostat handle.
Fan kit installation
1. Attach the fan assembly at the bottom edge of the in-
ner back with two () 1/4-0 x 3/4” hex head screws.
. Attach snapstat to the mounting holes on the underside
of the bottom with two () 1/4-0 pan head screws.
3. Attach the rheostat holder (provided with the stove)
under the right front wing of the bottom heat shield with
two () #10 sheet metal screws.
4. Attach the rheostat to its holder by inserting the rheo-
stat control shaft through the holder hole. Install the
retaining ring and rheostat knob onto the shaft.
5. Secure the rheostat cable to the underside of the bot-
tom heat shield using the wire tie provided and the
hole at the right rear edge of the heat shield.
6. Fan will not operate until stove reaches approximately
43° C (109° F).
7. Plug blower cord into a grounded outlet. Do not re-
move ground prong from plug. Route power cord to
avoid heat from the stove or other damage. Do not
route cord under or in front of appliance.
Fig. 20
Fan installation (Kit # FK6).
34
FANINSTALL
Rheostat
Knob
Rheostat
Snapstat
Screws
ST848
Hole for Wire
Tie to Secure
Cable
Rheostat
Holder