RAPIDO Instructions Manual
Status: April-03
22
Chlorine.organic
or
inorganic.
Substances
with active
Chlorine
Chloramin-T DAB 9
Clorina
Trichlorol
1,5
1,5
2
12
12
12
2,5
2,5
3
2
2
2
5
5
6
4
4
4
A
1
B
A
1
B
A
1
B
Lysoform
Lysoform
Per compounds
Apesin AP 100
2
Dismozon pur
2
Perform
2
Wofasteril
2
4
4
3
2
4
1
4
4
AB
AB
AB
AB
Tana Chemie
Bode Chemie
Schülke & Mayr
Kesla Pharma
1 Not sufficiently effective against myco bacteria especially in the presence of blood.
2 Not suitable for disinfection of surfaces noticeably contaminated with blood, or for porous surfaces like bare wood.
3 Not to be used for tuberculosis; preparation of lime milk: 1 part lime solution (calcium hydroxide) + 3 parts water.
A:
Suitable for killing vegetative bacterial germs including mycobacteria as well as fungi including fungal spores.
B:
Suitable for deactivation of viruses.
The actual situation in regard to disinfectants included in the RKI list could be ascertained by
requesting the Robert Koch Institute (RKI; homepage: www.rki.de).
All measures for disinfecting rehabilitative products, their components, or accessory parts are
recorded in a disinfection manual which includes at least the following information with the respective
product documentation appended:
Table 2 – Example of a disinfection report
Date of the
disinfection
Reason
Specification
Substance and concentration
Subscript
Abbreviations for the entries in column 2 (Reason):
V = infection suspected IF = actual infection W = recurrent I = inspection
Your dealer shall gladly assist you in the case of queries about disinfection.
Î
Only authorised experts (hygienist or someone appointed by him) trained in the functioning
and application of disinfectants, should apply disinfectants.
Î
Wear protective gloves to prevent skin irritation and take note of the information supplied with
the solution concerned.
Î
Application of disinfectants by unauthorised persons occurs at your own risk.
Î
Damage and injuries caused by improper handling of disinfectants are not the liability of the
wheelchair manufacturer.
Queries about disinfection should be directed to your dealer who shall gladly assist you further.
WARRANTY
Defects must be reported in writing within two weeks. We accept liability for processing or material
defects discovered later, calculated for the warranty period for the respective product group:
-
Electric wheelchairs:
2 years (framework only)
(...)
The following are excluded:
-
Damage caused by changing the structure of our products
- Worn
parts
-
Damage caused by the product or its user
-
Damage caused by external influences
-
Damage caused by not using original parts