6/30
03/2016
a. Low voltage control – Models with 1 speed
b. Low voltage control – Models with frequency inverter
4.3 - Models available
Warning:
. the rope diameter shown above corresponds to the recommended rope according to FEM 1 Am /
ISO M4 classification. It also corresponds to the capacity on the last layer.
. it is compulsory to ensure that the resistance coefficient of the rope complies with the lifted load
(FEM 1 Am / ISO M4).
TVI
1 T
2 T
3 T
4 T
5 T
6 T
7 T
8 T
9 T
10 T
05BT/10BT
05BT/09BT
03BT/06BT
02BT/05BT
03BT/07BT
02BT/06BT
02BT/06BT
02BT/05BT
02BT/05BT
03BT/05BT
Position of the electrical unit
(1)
(1)
(1)
(1)
(1) / (2)
(1) / (3)
(1) / (2)
(1) / (2)
(1) / (2)
(1) / (2)
A in mm
911
1050/1045 1065/1090 1169/1194 1194/1220 1224/1250 1241/1267 1241/1267 1288/1087 1314/1288
B in mm
290
420
420
520
520
650
700
700
840
840
C in mm
375
500
500
665
665
765
870
870
975
975
D in mm
125
219,1
219,1
292
292
323,9
355,6
355,6
406,4
406,4
E in mm
350
350
350
350
350
350
350
350
350
350
F in mm
525
590
590
600
600
600
720
720
720
720
G in mm
240
330
330
420
420
420
620
620
750
750
H en mm
12
16
16
22
22
22
30
30
32
32
I in mm
25
45
45
50
50
115
40
40
45
45
J in mm
23
32
32
30
30
30
50
50
47
47
K in mm
263
295
295
300
300
300
360
360
360
360
L in mm
188
262
262
350
350
395
455
455
515
515
M in mm
120
165
165
210
210
210
310
310
375
375
N in mm
716/748
823/902
823/902
905/984
954/1190 1013/1181 1103/1271 1133/1271 1176/1314 1176/1314
0 in mm
548/578
578/657
578/657
578/657
627/795
627/795
662/830
692/830
692/830
692/830
TVI
1 T
2 T
3 T
4 T
5 T
6 T
7 T
8 T
9 T
10 T
05VV/10VV
05VV/09VV
03VV/06VV
02VV/05VV
03VV/07VV
02VV/06VV
02VV/06VV
02VV/05VV
02VV/05VV
03VV/05VV
Position of the
electrical unit
(1)
(1) / (3)
(1) / (3)
(1) / (2)
(2) / (3)
(2)
(2)
(2)
(2)
(2)
A in mm
911
1050/1045
1065/1090 1169/1194 1194/1220 1224/1250 1241/1267 1241/1340 1288/1087 1288/1367
B in mm
290
420
420
520
520
650
700
700
840
840
C in mm
375
579/500
579/500
737/665
665
765
870
870
975
975
D in mm
125
219,1
219,1
292
292
323,9
355,6
355,6
406,4
406,4
E in mm
350
350
350
350
350
350
350
350
350
350
F in mm
525
590
590
600
600
600
720
720
720
720
G in mm
240
330
330
420
420
420
620
620
750
750
H en mm
12
16
16
22
22
22
30
30
32
32
I in mm
25
45
45
50
50
115
40
40
45
45
J in mm
23
32
32
30
30
30
50
50
47
47
K in mm
263
295
295
300
300
300
360
360
360
360
L in mm
188
262
262
350
350
395
455
455
515
515
M in mm
120
165
165
210
210
210
310
310
375
375
N in mm
716/748
823/902
823/902
905/1052
1022/1122 1067/1220 1103/1271 1133/1271 1176/1314 1176/1314
0 in mm
548/578
578/657
578/657
578/657
627/795
627/795
662/830
692/830
692/830
692/830
Summary of Contents for TVI Series
Page 18: ...18 30 03 2016 11 Declaration of EC conformity...
Page 19: ...19 30 03 2016 12 Appendixes A References of parts B Load limiter C Limit switch optional...
Page 20: ...20 30 03 2016 A References of parts TVI 1T...
Page 22: ...22 30 03 2016 TVI 2T 3T...