29/30
07/2016
8/ Key
save
.
0000
is displayed. (Load the winch to the desired cutoff value).
9/ Operate the rise (online reading of the Amps). Example 5A at XX kg cutoff desired.
10/ back in
C041
with the key
save
then
navigate
,
save
and then
up
. Setting at 5A
(example) with the key
up
or
down
and
save
.
11/ Key
navigate
D001
then
save
and use.
The default reset E12 is made by the stop reset key
or the key switch on the electrical cabinet.
c)
With SJ200 variator
Use of the integrated keyboard
Setting of the curent limitation via the speed inverter SJ200 :
1/ Winch turned on display
0000
, key
display
D001
.
2/ Arrow
2
=
H - - -
.
3/ Arrow
2
=
C - - -
.
4/ Key
= C001
the arrow
1
until
C041
.
5/ Key
display the value in Amps, key
until maximum value. Then key
to validate.