STAGEMAKER®
-
40
VERLINDE reserves the right to alter or amend the above information without notice.
11/2008
11 Maintenance – Replacement of hoist
(inverter
Æ
250kg)
11.1 Maintenance table
Check
Interval *
Qualification of the
customer’s personnel
Brake operation
Daily Operator
Visual inspection of the chain
Daily
Operator
Suspension of the control box by the steel wire
Daily
Operator
Cleanness and lubrication of the chain
Monthly
Operator
Slipping clutch operation
Monthly
Operator
End limit switches operation
Every 3 months
Operator
Measuring of the wear on the chain
Every 3 months
Operator
Measuring of the wear on the hooks
Annually
Qualified mechanic
Tightening of the hook block screws
Every 3 months
Operator
Visual checking of hook and hook bottle
Every 3 months
Operator
Checking of the locking plate screws
Annually
Operator
Checking of the tightness of the brake screws
Annually
Qualified mechanic
Lubrication of the idler sprocket
Annually
Operator
Checking of the screw tightening torques and checking for signs of corrosion
Annually
Qualified mechanic
Adjustment of the slipping clutch and brake
Annually
Qualified mechanic
Lubrication of the gears
Lubricated for life
,
* These intervals should be shortened depending on national regulations
,
These intervals should be shortened if the hoist is used a lot, if it is used with maximum
loads or in difficult ambient conditions.
11.2 Lubricants
Lubrication point
Specifications
Possible brands
Quantity
Chain
Oil or liquid grease
Chain lubricating fluid (Ceplattyn or similar)
As required
Idler sprocket
▲
slide b bearing
Grease (
without MoS2
)
KP 2 (DIN 51 502)
Soap-based lithium
Approx. drip point + 260°C
Worked penetration 265 - 295°
Operating temperature
- 20°C à + 130°C
Aral
: Aralub FK 2
BP
: BP Energrease LS - EP 2
Esso
: Unirex N2
Mobil
: Mobilgrease HP
Shell
: Shell Alvanio EP Grease 2
DEA
: Paragon EP 2
Fuchs
: Renolit Duraplex EP 2
As required
Gears
z
Shell
:
Transaxle Oil 75W-90
0,6
L
Oil the chain regularly