background image

 15 

LIMITED WARRANTY

 

VeriPure, LLC warrants to the original purchaser of the VeriPure ®System products that such equipment is free from defects in 
materials and workmanship. 

If within one (1) year from the date of purchase, any product purchased from VeriPure, LLC shall prove to be defective in   
materials or workmanship, the VeriPure, LLC product shall be repaired or replaced, at VeriPure’s sole discretion,                             
at VeriPure, LLC's expense.  

This warranty shall not apply to: 

a. 

Product that has been damaged by improper installation. 

b. 

Product that has been improperly used or maintained. 

c. 

Product subjected to temperatures below 35 or over 120

F. 

d. 

Product operated in water pressures exceeding 90 psi. 

e. 

Product damaged after delivery. 

f. 

Product that has not been properly maintained. 

VeriPure® Maintenance Kits are specifically not covered under this warranty. 

Requests for service under this warranty shall be made by contacting a local distributor or dealer in a timely manner following 
discovery of the claimed defect. Any claim under this warranty must be made within 30 days following the expiration of the one 
year warranty. 

VeriPure, LLC reserves the right to improve designs or change specifications at any time without any contingent obligation to 
owners of products previously sold. 

VeriPure, LLC shall not be liable for any consequential, incidental or contingent damages. The foregoing warranties are         
exclusive and in lieu of all other express warranties. Implied warranties, including but not limited to the implied warranties of 
merchantability and fitness for a particular purpose, shall not exceed beyond the duration of this applicable express warranty 
provided herein. It is acknowledged that select states do not permit exclusive or limitations of incidental or consequential 
damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to you. 
This warranty extends to you specific legal rights and you may also have other rights which vary from state to state. 

2425 HUTSON ROAD 

GREEN BAY WI, 54303 

(920) 613-6771 

www.veripure.com 

Summary of Contents for VERIPUREVPC7000

Page 1: ...1 OWNERS MANUAL VERIPUREVPC7000 REVISED 4 13 2020...

Page 2: ...m THANK YOU FOR CHOOSING VERIPURE PLEASE TAKE A FEW MOMENTS TO FILL IN THE INFORMATION BELOW SAVE THIS MANUAL AS A CONVENIENT INFORMATION SOURCE FOR YOUR VERIPURE SYSTEM Date of Purchase Purchased Fro...

Page 3: ...S TURN OFF THE WATER SUPPLY AT THE SINK OR WATER SOURCE AND UNPLUG POWER JACK FROM THE VERIPURE SYSTEM BEFORE PERFORMING ANY MAINTENANCE ACCESSORIES DO NOT USE ANY ACCESSORIES INCLUDING FILTER CARTRID...

Page 4: ...OR 3 MINUTES WITH VERIPURE WATER FOOD ITEMS PLACE IN A BOWL COLANDER OR STRAINER RINSE WITH VERIPURE WATER STORING WATER SELECT A CONTAINER THAT IS FOOD GRADE QUALITY SUCH AS GLASS OR STAINLESS STEEL...

Page 5: ...FORMANCE LIMIT YOUR VERIPURE SYSTEM TO 70 PSI OF WATER PRESSURE VERIPURE RECCOMENDS A MINIMUM WATER PRESSURE OF 50 PSI LOW WATER PRESSURE WILL CAUSE YOUR VERIPURE SYSTEM TO PRODUCE A LOWER QUANTITY OF...

Page 6: ...BER AND OR ELECTRICIAN INSTALL YOUR VERIPURE SYSTEM IF YOU CHOOSE TO INSTALL THE UNIT YOURSELF AND ARE IN NEED OF ASSISTANCE PLEASE CALL 920 613 6771 FOR ASSISTANCE INSTALLATION OF THE VERIPURE SYSTEM...

Page 7: ...SURIZED BEFORE REMOVING FITTINGS PUSH IN THE COLLET AGAINST THE FACE OF THE FITTING WITH THE COLLET HELD IN THIS POSITION THE TUBBING CAN BE REMOVED THE FITTING CAN THEN BE RE USED FLUSHING INSTRUCTIO...

Page 8: ...rant application Special application Compact size 16 25 L x 6 W x 18 25 H 41 275cm L x 15 24cm W x 46 35cm H Light weight 9 0 lbs 19 8 kg No water wasted Low Voltage DC operation with 115 VAC UL wall...

Page 9: ...is malfunctioning LED READOUT INSTALLED VERIPURE There are two maintenance requirements for your VeriPure System 1 Change the filter cartridge assembly when indicated by the LED readout on your VeriPu...

Page 10: ...ss water and remove and discard of used filters 4 Wipe out any debris or build up inside of canister TO INSTALL NEW FILTERS 1 Open new carbon sediment filters from wrapping packaging 2 Place filter in...

Page 11: ...ve the Dielectric tube from the VeriPure housing by sliding the Dielectric out IN A STRAIGHT LINE until the Dielectric tube is completely separated from the VeriPure housing 5 The old Dielectric tube...

Page 12: ...AND FIRMLY SEATED WITH NO EVIDENCE OF WATER LEAKAGE TROUBLE SHOOTING GUIDE At VeriPure Inc we expect your VeriPure System to function properly for years as long as you perform the maintenance accordi...

Page 13: ...URE WILL NOT ALLOW YOUR SYSTEM OZONATION COMPONENTS TO TURN ON REGAIN INCOMING WATER PRESSURE TO MINIMUM OF 50 PSI CONTACT YOUR PLUMBER OR MUNICIPALITY DROP IN OR NO WATER FLOW PLUGGED FILTER CHANGE Y...

Page 14: ...OES THE OZONE AFFECT THE TASTE OF THE WATER Initially there is a slight aroma of ozone This dissipates after a short period of time approximately 20 seconds IS THE OZONE GAS RELEASED INTO THE AIR BY V...

Page 15: ...aler in a timely manner following discovery of the claimed defect Any claim under this warranty must be made within 30 days following the expiration of the one year warranty VeriPure LLC reserves the...

Reviews: