7
INSTALLATION INSTRUCTIONS
BEFORE INSTALLING
1.
YOUR VERIPURE® SYSTEM
IS DESIGNED TO BE USED WITH
COLD WATER ONLY.
2.
NEVER RUN WARM OR HOT WATER
THROUGH YOUR VERIPURE® SYSTEM AS HOT WATER
CAN DAMAGE THE CARBON BLOCK FILTER.
3.
WATER TEMPERATURES
ABOVE 90° F CANNOT CONTAIN DISSOLVED OZONE; THUS
ELIMINATING DISINFECTION. WATER TEMPS APPROACHING 85° F REQUIRE LONGER
PERIODS OF CONTACT TIME FOR DISINFECTION PURPOSES.
4.
FOR OPTIMAL PERFORMANCE
, LIMIT YOUR VERIPURE® SYSTEM TO 70 PSI OF WATER
PRESSURE. VERIPURE® RECOMMENDS A MINIMUM WATER PRESSURE OF 50 PSI. LOW
WATER PRESSURE WILL CAUSE YOUR VERIPURE® SYSTEM TO PRODUCE A LOWER
QUANTITY OF FILTERED AND OZONATED WATER.
5.
POWER REQUIREMENTS
ARE 120 VAC 60 HZ. USE AC ADAPTER PROVIDED WITH YOUR
SYSTEM.
NOTE: VERIPURE® UNITS ARE DESIGNED TO BE UNDER CONTINUAL WATER PRESSURE WHEN
INSTALLED AND NOT IN USE, THE ON/OFF VALVE AND OR FAUCET SHOULD BE ON THE
OUTLET OF THE VERIPURE AT OR BETWEEN THE POU AND VERIPURE® UNIT. THIS ENSURES
PROPER FUNCTION ON THE VERIPURE® .
VPC5000 INSTALLATION INSTRUCTIONS BEGIN ON NEXT PAGE (PAGE 8)