5.6 TURNING THE PRODUCT OFF IN THE UNLIKELY EVENT OF A
REMOTE HANDSET OR EFC TRIM SWITCH MALFUNCTION.
a)
In the unlikely event of the remote control handset or EFC trim switch
malfunctioning (or if lost or broken) after the appliance has been turned on,
the fire can be turned off via the emergency shut off switch on the control
panel.
b)
To turn the product off, firstly remove the ashpan from the fire.
c)
Press and hold the emergency shut off switch until the fire shuts down.
The process may take up to sixty seconds to complete. (see Fig. 3
below).
d)
When the fire has shut down, release the emergency shut off switch.
e)
The appliance will now remain in the “off” position until activated by the
remote handset / EFC trim switch (whichever is applicable).
Fig. 3
REPLACING THE BATTERIES (REMOTE & EFC MODELS ONLY)
ENSURE THE FIRE IS COOL BEFORE REPLACING BATTERIES
Remove the ashpan cover. The battery pack is located on the right hand side side
of the burner unit at the bottom. Carefully remove the pack and remove
batteries. Replace in the reverse order using 6 off 1.5V AA Alkaline Battery.
It is
important that only an alkaline battery is used, otherwise premature battery
failure and leakage may result.
Emergency Shut Off
Switch Position on
Control Panel.
48