background image

4

5

Button and display description

Current room temperature

Heating element 
warming

Day of the week

Thermostat on

On/off

Down

Up

Clock

Mode

Current floor temperature

Installing and wiring the thermostat

To mount the thermostat to the wall box/wall socket, first open the 
thermostat by gently pushing the tabs in the buttom of the thermo

-

stat. To fix the thermostat, screw in properly sized screws into the 
wall socket/wall box.
When proberly fastend and cables connected (see diagram below), 
mount the frontpanel to the backpart again.

Electrical wall 

box/socket

Wiring diagram

 

Remote sensor

Model: Veria Control T4

5

Mains voltage:  

85-240V

~

ra
IP 

ting: 

IP30

S1

Load

S2

L

Load

N

13A

Max. load

:

Temperature:   0T30

85-240V~

Max 
13A

EN

EN

Timer mode activated

Frost protection mode activated

Summary of Contents for Control T45

Page 1: ...Veria Control T45 Installation guide Installationsanleitung Installasjonsveiledning Installationsguide Asennusopas Installationsvejledning EN DE NO SE FI DK...

Page 2: ...tionality Activate Timer Mode 10 Programming the timer 10 Technical specifications 14 Veria Warranty 15 EN Introduction Veria Control T45 is an advanced digital timer thermostat which allows you to co...

Page 3: ...tly pushing the tabs in the buttom of the thermo stat To fix the thermostat screw in properly sized screws into the wall socket wall box When proberly fastend and cables connected see diagram below mo...

Page 4: ...re floor temperature is prioritized over room temperature Change between the above floor heating modes With the thermostat turned off Press and for 6 seconds Select mode 1 to 5 see table on next page...

Page 5: ...e the floor temperature max limit program mode 3 and 5 With the thermostat turned off Hold the M button for 10 seconds until the display shows Now let go of the button M and the display will show SET...

Page 6: ...uous process so it is a good idea to have the periods written down for reference when programming the thermostat Note for the weekend you will also need to program 2 periods You can choose one of the...

Page 7: ...or the weekday you are now able to set the switching times for weekend Sa Su will be displayed Use Up Down key to set the required start time Press to accept this setting Use the Up Down key to set th...

Page 8: ...rrent rating 13A resistive load Mains voltage 85 240V Dimensions 86 x 86 x 13 mm WxHxD Fixing screw width 60mm Housing ABS PC Flame Retardent Operating rating 0 30 C 5 95 RH non con densing Veria warr...