8
9
Basic functionality
SETTING THE CLOCK
With the thermostat turned on.
Press “
” once, hour will be flash.
Use the Up/Down key to select the hours.
Press “
” again, minute will be flash.
Use the Up/Down key to select the minutes.
Press “
” button again, till the week day flashes.
Use the Up/Down key to select the day of the week.
After setting week day do not press any further buttons and the
thermostat will go back to normal operating mode mode.
SETTING THE FLOOR TEMPERATURE MAX. LIMIT
This function is used for wooden floors mainly and is
only
available
in program modes using the floor sensor (program mode 3 and 5)
The temperature setting should be maximum 35C, which is also the
default set point of the thermostat.
If you choose to control the floor temperature solely by the floor
sensor (program mode 2) the max. floor temperature is set for 35C
and can‘t be changed.
Change the floor temperature max. limit (program mode
3 and 5)
With the thermostat turned off.
Hold the “
M
” button for 10
seconds until the display
shows “
”.
Now let go of the button “
M
” and the display will show “SET”.
You are now prompted to enter the maximum floor temperature
(temperature range 20
°C-45
°C)
Basic functionality
READING THE FLOOR TEMPERATURE (only in program mode 3
and 5)
With the thermostat turned on.
Press “
M
” once, the “
FT
” will be flashed, and the display will
show the floor temperature.
In program mode 2 (floor sensor) the display always shows the current
floor temperature.
In program mode 1 and 4 (room sensor) the display always shows the
current room temperature.
FROST PROTECTION MODE
To enable frost protection mode.
With thermostat turned off.
Press “
M
” for 3 seconds.
Select 01 (00 = disabled)
When enabled and thermostat has been turned off, the heating will be
activated if the room/floor temperature is lower than 5
°C; the heating
will be stopped if the room/floor temperature is higher than 7
°
C.
When frost protection mode has been enabled the display will show
“
”.
EN
EN