Maintenance
Maintenance
Maintenance
To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
To avoid injury from fire, explosion, perform all
maintenance and repair outside of hazardous
location.
Maintenance
Maintenance
Maintenance Schedule
Schedule
Schedule
Items such as balls and seats, diaphragms, and other
seals will wear out from normal pump operation.
These items must be inspected periodically to ensure
that they are not worn. Replace them if they are worn
or damaged. Establish a preventive maintenance
schedule based on the pump’s service history.
Scheduled maintenance is especially important to
prevent spills or leakage due to diaphragm failure.
Lubrication
Lubrication
Lubrication
The pump is lubricated at the factory. It is designed
to require no further lubrication for the life of the
bearings. There is no need to add an inline lubricator
under normal operating conditions.
Tighten
Tighten
Tighten Threaded
Threaded
Threaded Connections
Connections
Connections
Before each use, check all hoses for wear or damage
and replace as necessary. Check to be sure all
threaded connections are tight and leak-free. Check
mounting bolts. Check fasteners. Tighten or retorque
as necessary. Although pump use varies, a general
guideline is to retorque fasteners every two months.
See
Flushing
Flushing
Flushing and
and
and Storage
Storage
Storage
To avoid injury from fire, explosion, or electric
shock, always ground equipment and waste
container. To avoid static sparking and injury from
splashing, always flush at the lowest possible
pressure.
• Flush before first use.
• Flush at the end of the day, before storing, and
before repairing equipment.
• Flush at the lowest pressure possible. Check
connectors for leaks and tighten as necessary.
• Flush with a fluid that is compatible with the fluid
being dispensed and the equipment wetted parts.
• Always flush the pump and relieve the pressure
before storing it for any length of time.
NOTICE
NOTICE
NOTICE
Flush the pump often enough to prevent the
fluid you are pumping from drying or freezing in
the pump and damaging it. Store the pump at
0°C (32°F) or higher. Exposure to extreme low
temperatures may result in damage to plastic parts.
859.0634
19
Summary of Contents for Verderair VA-E80
Page 24: ...Dimensions Dimensions Dimensions Dimensions Aluminum pump with compressor 24 859 0634 ...
Page 25: ...Dimensions Aluminum pump without compressor 859 0634 25 ...
Page 27: ...Dimensions Polypropylene pump with compressor 859 0634 27 ...
Page 28: ...Dimensions Polypropylene pump without compressor 28 859 0634 ...
Page 30: ...Dimensions Stainless steel pump with compressor 30 859 0634 ...
Page 31: ...Dimensions Stainless steel pump without compressor 859 0634 31 ...