![Verco Oblique Adapt Assembly And Operating Instructions Manual Download Page 17](http://html.mh-extra.com/html/verco/oblique-adapt/oblique-adapt_assembly-and-operating-instructions-manual_1003541017.webp)
17
Display
Source
Remedying
E62
Overcurrent
Control unit - Overall current overload
E63
External sensor or the
cable is not connected
External sensor or other add-on module
is not connected.
Check the plug connection if necessary
E64
Authentication error
Reset the table.
E65
Overcurrent or short circuit
If errors occur during the drive.
Collision? -> resolve if necessary
max. Load exceeded -> remove the load
from the table.
E67
Overvoltage
Power or power supply fluctuations?
Verify that the correct power voltage/
frequency is applied.
E70
Change of the drive
configuration
Unplug the system and wait 5 Min.
seconds, then reset table.
E81
Internal fault
Memory or reset fault?
Reset the table (for service: If necessary
import set of parameters new) .
If it is not possible to resolve an error as described, disconnect the power cord, wait
a few minutes and reset the table again!
If the error still occurs, remove the table from power and contact Customer Support.
(Error Code list is valid from firmware 1.7.5 and higher!)