Oblique Adapt
Assembly and Operating Instructions
June 2013
Page 1: ...Oblique Adapt Assembly and Operating Instructions June 2013 ...
Page 2: ...troubleshooting 5 Before the operation 5 During the operation 5 Repairs 6 Warranty 6 Maintenance Cleaning 6 Assembly 7 Reset 11 Operation 11 with HDU Unit 12 Troubleshooting 15 Error Code in the display of the handset optional 16 Technical Data 18 Tests and Certifications 19 ...
Page 3: ...s before leaving our factory If you still have problems with your table base you can always contact our service department The assembly of the table frame must be made in accordance with this manual Changes to the table frame or improper use may affect the safety function and life This manual is for all OBLIQUE Adapt sit stand tables with HDU provided Due to different models or types pictures can ...
Page 4: ...s assembled this sit stand desk or is a user of the desk must have access to these instructions ర If the product is obviously damaged it must not be installed or continue to be used ర This table frame is not intended for use by persons including children with reduced physical sensory or mental abilities or lack of experience and or knowledge Children should be supervised to ensure that they do not...
Page 5: ...nstalled in accordance with this manual t Check the operating voltage of the table of the local power supply see label on the control EU Standard 230V t Set the plug connections from the Handset and the Columns to the control unit t Connect the power cable to the controller During the operation t If the drives or the control unit during operation may cause unusual noises or smells disconnect the p...
Page 6: ...ormed only by authorized service personnel The sit stand table must not be handled or used improperly and no changes made to the table frame are allowed or this will invalidate the warranty For more information please refer to our Terms and Conditions Maintenance Cleaning Remove dust and dirt on a regular basis from the table frame especially from the guide tubes and make sure that no damage or cr...
Page 7: ...first on the columns please use the bolts to the table frame drawing The max tightening torque is 10 Nm The max Screwing depth of the M10 in the Driving column is 9 mm With asymmetrical frames C form please note that a left and a right side panel is required 2x Screws M10 Foot Column WARNING The max screwing depth in the Column is 9 mm If the Screw goes deeper then the motor may become damaged Ple...
Page 8: ... max If a CPU holder are integrated into the system please con nect these over the two inner screws over the top plate of the column to the beams Please note that the max tightening torque for the screws is 20 Nm 4x Screws M8 The 2x internal screw are to screw in the threads of the beams The 2x external screw are to screw in the threads of the desktop support Desktop Support Beams ...
Page 9: ...ou can place the controlbox excentric under the tabletop For very long tables you can use a motorextension cable 6 Connect the motorcables form the column to the controlbox The plug connection has to click into place If a controlbox is used which has mire plug terminals than needed you always have to start to connect to M1 The redundand terminals can be left open 7 Make the connection between the ...
Page 10: ...10 Connections to the control unit M1 M3 Connectors for the drives HS Connectors for the handset AC Connector for the power cord 3 pin Sensor ...
Page 11: ...d about 5 seconds until a slight movement of the table drops down to the machine zero point and back up to the operation zero point and the table stops moving after that release the button If the button is released too early this leads to a malfunction at the table If this occurs you must repeat the process The upper end position is preset in the control unit For this reason only control units tha...
Page 12: ... Operation with HDU handset with display memory optional This handset is equipped with a display for displaying the current table height in centimeters or inches in addition the storage of 4 memory positions desk height is possible The Reset LED indicates that a reset is required see section Reset It lights until the reset is completed The Info LED indicates that the control unit has detected an e...
Page 13: ...rt of the desired height Change the height noted in display from cm or inches S5 Menu The height display of the handset can be set both in centimeters or inches With the help of the S5 menus the unit can be changed If the display has been set to centimeters the height will be displayed in inches after the menu selection of if inches have previously been displayed you can change to displaying centi...
Page 14: ...ntimeters or inches with the UP or DOWN button Confirm the entry by pressing the S button To exit the menu without making a selection you can wait about 10 seconds and the altitude display appear again Optional equipment External sensor for collision detection The sensor bridge 9903 2200 is responsible for an early detection of a possible collision of the table frame with other components or objec...
Page 15: ...g capacity is exceeded Reduce the weight or load on the desktop max Time limit exceeded Control is activated automatically after about 9 minutes later Defective drive Contact customer service Defective control unit Contact customer service Handset is defective Replace the Handset Table moves slowly down Control unit expects new reset see page 11 Table moves only slowly max Lifting capacity is exce...
Page 16: ...lve if necessary max Load exceeded remove the load from the table If the problem still exists after that please contact customer service E25 M2 Overcurrent E26 M3 Overcurrent E36 M1 Not connected Motor not connected Check cable connector to the drive Reset the table E37 M2 Not connected E38 M3 Not connected E48 Overcurrent drive 1 Collision resolve if necessary max Load exceeded remove the load fr...
Page 17: ...d from the table E67 Overvoltage Power or power supply fluctuations Verify that the correct power voltage frequency is applied E70 Change of the drive configuration Unplug the system and wait 5 Min seconds then reset table E81 Internal fault Memory or reset fault Reset the table for service If necessary import set of parameters new If it is not possible to resolve an error as described disconnect ...
Page 18: ... 18 min off 1 Drive with COMPACT 2 N 0 0 6 y t i c a p a c t f i l m u m i x a M 60 kg Adj Range depending on version View drawing Maximum Power consumption Primarily 338 W 2 Gear Drive with COMPACT 2 N 0 5 7 y t i c a p a c t f i l m u m i x a M 75 kg Adj Range depending on version View drawing Maximum Power consumption Primarily 338 W 3 Gear Drive with COMPACT 2 N 0 5 7 y t i c a p a c t f i l m...
Page 19: ...2 2005 Electromagnetic compatibility EMC EN 61000 6 3 2007 Electromagnetic compatibility EMC Electrical Safety Low Voltage Directive 2006 95 EC EN 50366 2003 A1 2006 Electrical apparatus for household and similar purposes Electromagnetic Fields EN 60335 1 2002 A1 2004 Safety of electrical equipment for A11 2004 A12 2006 A2 2006 Household and similar purposes ...