background image

Nero BackItUp & Burn 
Essentials Software

Nero BackItUp & Burn Essentials software is included on the hard drive. 
Double click the Nero folder on the drive and then double click the setupx
fi le to start installation. The Nero installation window will appear. Follow up
the set up wizard to install the software. Note: nero BackItUp software is
only compatible with Windows XP / Vista, and Windows 7.

Connecting To Your Computer

This Verbatim external hard drive provides both USB 2.0 and eSATA 
connections. You can connect your drive to a computer with either USB
or eSATA, but not both at the same time. The cables you will need for your
desired connection type and the steps to connect are summarized below.

Connection Type

Cable

USB

USB-A

     

USB *

* Some computers

may require auxiliary

power cable.

USB-A

     

+

+

+

USB-A

Powered eSATA

USB / eSATA

       

eSATA 

(non-powered)

eSATA

+

+

+

USB-A

Summary of Contents for GT

Page 1: ...Store n Go Portable Hard Drive eSATA USB2 0 Combo User Guide English ...

Page 2: ...the supplied Auxiliary DC Power Cable between the computer s second USB port and this Auxiliary Power DC Input jack Furthermore if your computer s eSATA port is a standard non powered eSATA interface then you must also use the Auxiliary Power DC Power Cable in conjunction with the Powered eSATA cable in order to operate the drive over eSATA 2 USB Connector Use this connector to attach the drive to...

Page 3: ... connection through the standard eSATA connector This is inconvenient for portable external hard drive applications because it means use of the portable drive requires both a data cable and a separate power cable or AC power adapter to power the drive Recently many laptop manufacturers have included a combination USB eSATA connector that can be used in conjunction with a special Powered eSATA Cabl...

Page 4: ... software is only compatible with Windows XP Vista and Windows 7 Connecting To Your Computer This Verbatim external hard drive provides both USB 2 0 and eSATA connections You can connect your drive to a computer with either USB or eSATA but not both at the same time The cables you will need for your desired connection type and the steps to connect are summarized below Connection Type Cable USB USB...

Page 5: ...lugged into non Hi Speed USB hub This does not indicate a problem because the drive is compatible with both USB 1 1 and USB 2 0 ports Simply close the message and proceed However in this case the drive will operate only at USB 1 1 speeds Note 2 USB or eSATA under Mac OS X 10 2 Mac OS X version 10 2 will not mount any single FAT32 formatted MS DOS partition greater than 128GB To work around this OS...

Page 6: ...your unit Simply unplugging the unit without first following the instructions below may result in damage to your unit and or loss of data For Windows Users 1 If you have files located on your drive open in any applications close them 2 Click the Unplug or Eject Hardware button in the System Tray 3 Select your drive from the menu that appears 4 After a moment Windows will display a message that your ...

Page 7: ...ough most of our customers find this content sufficient to put them back on the right track this page also lists ways in which you can contact the Verbatim Technical Support Team directly Europe For technical support in Europe e mail drivesupport verbatim europe com or call 00 800 3883 2222 in the following countries Austria Belgium Denmark Finland France Germany Hungary Italy Luxemburg Monaco Nethe...

Page 8: ...y Italy Luxembourg Monaco Netherlands Norway Poland Portugal Republic of Ireland Spain Sweden Switzerland and United Kingdom call 00 800 3883 2222 All other European countries call 353 61 226586 You can email drivesupport verbatim europe com Product replacement is your sole remedy under this warranty and this warranty does not apply to normal wear or to damage resulting from abnormal use misuse ab...

Page 9: ...nt generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipmen...

Page 10: ...quipment at end of life The WEEE logo shown at the left on the product or on its box indicates that this product must not be disposed of or dumped with your other household waste For more information about electronic and electrical waste equipment disposal recovery and collection points please contact your local municipal household waste disposal service or shop from where you purchased the equipm...

Page 11: ...for testing evaluation EN 55022 1998 A1 2000 A2 2003 EN 61000 3 3 1995 A1 2001 EN 55024 1998 A1 2001 A2 2003 IEC 61000 4 2 1995 A1 1998 A2 2000 IEC 61000 4 3 2002 A1 2002 IEC 61000 4 4 1995 A1 2000 A2 2001 IEC 61000 4 5 1995 A1 2000 IEC 61000 4 6 1996 A1 2000 IEC 61000 4 8 1993 A1 2000 IEC 61000 4 11 1994 A1 2000 RoHS Compliance This product is in compliance with Directive 2002 95 EC of the Europe...