SENSOR CONFIGURATIONS
A2C15587600
5
Manually set the 5-points calibration
into the table [D] for the selected sensor.
The graph [G] will display the calibration being set.
The example above is for a standard 3-180
Ω
fuel level sensor.
6
Upload the configuration
to the display
.
Press the SET button [F] to write the configuration for the specific pin.
A popup will appear as a safety confirmation.
Press the READ button [E] to read back from the display the configuration for the
pin defined in [A].
ADJUSTING THE SPEED CORRECTION FACTOR
The speed offset factor lets you align the speed through water (STW) to the actual speed.
If the measured speed differs from the real boat speed for more than 0.5 kn, this factor can
be adjusted.
Increasing the offset factor reduces the displayed speed through water (STW).