SENSOR CONFIGURATIONS
A2C15587600
FUEL LEVEL SENSOR CALIBRATION
1.
In the input configuration menu described
before, select “Calibration” to open the
sensor’s calibration options.
2.
Select
Tank volume
to set the tank’s
capacity (not mandatory).
3.
Select
Sensor type
, then select the sensor
type among the proposed standard ones.
4.
Select
Calibration
, then select the one or
three-point calibration procedure (
Do 1
point cal/Do 3-point cal
).
Calibration instructions and the ohmic value
read in real-time from the sensor [A] appear.
5.
Empty the tank and wait for the read value to
stabilize. Then confirm by pressing ENTER.
6.
For three-point calibration, follow the on-
screen instructions.
7.
Hold down the MENU button to return to
the data pages.
OTHER SENSORS’ CALIBRATION
1.
In the input configuration menu described
before, select
Calibration
to open the
sensor’s calibration options.
2.
Then select the three-point calibration
procedure by accessing
Do 3-point cal
.
Calibration instructions and the ohmic value
read in real-time from the sensor appear.
3.
For fresh and waste water sensors the tanks
must be drained, then wait for the read value
to stabilize. Confirm the reading by pressing
ENTER.
4.
Proceed with all calibration points following
the wizard.
5.
Hold down the MENU button to return to
the data pages.
Summary of Contents for OceanLink 4.3
Page 1: ...A2C15587600 OCEANLINK 4 3 MARINE DISPLAY USER MANUAL rev AB EN DE IT FR ES...
Page 8: ...INSTALLATION A2C15587600...
Page 29: ...SENSOR CONFIGURATIONS A2C15587600 CONFIGURE A SENSOR CONNECTED TO THE DISPLAY...
Page 44: ...A2C15587600 OCEANLINK 4 3 MARINE DISPLAY BENUTZERHANDBUCH rev AB EN DE IT FR ES...
Page 51: ...INSTALLATION A2C15587600...
Page 73: ...SENSOR KONFIGURATIONEN A2C15587600 EINEN MIT DEM DISPLAY VERBUNDENEN SENSOR KONFIGURIEREN...