Veracity Coldstore CSTORE15-3U Quick Start Manual Download Page 11

VERACITY 

COLDSTORE

  |  

CS

TORE

15-3U

 QUICK START GUIDE  | 

REV 3.0.

3

  |  

October 2018

  |  11 

12

 

Click 

Done

The My Site window is shown. 

If a COLDSTORE entry is shown, you have successfully added the COLDSTORE and it is ready for 
configuration. Skip to section L). 

If no COLDSTORE entry is shown, ensure that you selected the COLDSTORE in the Discovery 
window, specified correct credentials for the COLDSTORE in the Selected Devices window, that 
you clicked 

Add to site

 and were shown the Complete! confirmation window before you clicked 

Done

L) System Configuration

This section assumes you have installed SITESCAPE and have added your COLDSTORE to My Site. If
you have not done this, please complete section K) before continuing.

Aside for using SITESCAPE to make changes to the COLDSTORE network settings required for your
installation, some other changes that should be considered are: enter the address of the primary NTP
server on the network, and set the correct time zone for the geographical location of the COLDSTORE.

Also, SITESCAPE can be used to query the COLDSTORE’s array and disk status e.g. checking the
loaded disks are visible, correct and are writable.

See COLDSTORE User’s Guide gives full details of all operations possible with SITESCAPE.

 

Correct time-sync may be essential for correct operation, depending upon application.  It is strongly

recommended that a master NTP time server system be added to the network.  Veracity’s TIMENET PRO is a
suitable hardware device – see www.veracityglobal.com for full details.

 

If the network settings of the COLDSTORE are to be changed, this should be the last operation done

using SITESCAPE. After changing the network settings, it will be necessary to re-add the COLDSTORE to My
Site to interact with the COLDSTORE. Also, depending on the network settings changes made, it may be
necessary to change the computer’s network settings in order to communicate fully with the COLDSTORE.

To configure the network address of your COLDSTORE proceed as follows:

1

 

Using the Windows Start Menu, navigate to All Apps>Veracity. Click SITESCAPE. 

If Window User Account Control is enabled, click 

Yes

 when prompted. 

The SITESCAPE splash screen is shown momentarily then, later, the SITESCAPE application main 
window is displayed. 

2

 

Click the 

Site tools

 link in the left-hand panel. 

Site tools expands to show a number of tools. 

3

 

Click 

COLDSTORE configuration

The COLDSTORE Configuration window is displayed in the right-hand panel. 

Summary of Contents for Coldstore CSTORE15-3U

Page 1: ...Quick Start GUIDE COLDSTORE CSTORE15 3U Version 3 0 3...

Page 2: ...Overview F Chassis Mounting G System Connections H Disk Loading I Power Up Sequence J Front Panel Menu K COLDSTORE Set up and Maintenance Software SITESCAPE Installing SITESCAPE Getting Connected L Sy...

Page 3: ...t No 2009 502184 The storage array should NOT be moved once powered up as this is very likely to cause disk damage this applies to all types of disk storage arrays Information in this guide is subject...

Page 4: ...running Windows 7 or later Windows operating system Ethernet Network including network cables and a switch Preferred Video Management System see website for list of supported systems E System Overview...

Page 5: ...unit on If network connection redundancy is required a second network cable can be connected between your network switch and the network port labelled ETH2 but before connecting ensure that the COLDS...

Page 6: ...acity s technical support team Fitting 2 5 disk drives to the rear drive bays will not provide performance benefits and could the correct operation of the COLDSTORE I Power Up Sequence Once the disks...

Page 7: ...the configuration of your firewall and ensure that the SITESCAPE has full unblocked network access For more information about installing and using SITESCAPE see COLDSTORE User s Guide Installing SITE...

Page 8: ...have two Ethernet connections labelled ETH1 and ETH2 By default connection ETH1 has IP address 10 0 0 140 subnet mask 255 255 255 0 and gateway 10 0 0 1 This section assumes that the network settings...

Page 9: ...ORE tab If a warning dialog or other notification is shown by a network firewall protection application choose to allow the SITESCAPE application full access to the network 8 Click the COLDSTORES tab...

Page 10: ...RE is eventually listed but with status offline and with error Device not found and a manually entered IP address for the COLDSTORE was used then it is possible that SITESCAPE is being prevented from...

Page 11: ...correct and are writable See COLDSTORE User s Guide gives full details of all operations possible with SITESCAPE Correct time sync may be essential for correct operation depending upon application It...

Page 12: ...at protocol 7 Click the IPV4 protocol tab The IPV4 Protocol tab for ETH1 connection of the selected COLDSTORE is shown 8 Enter the network settings in IPV4 format as required for your installation Upd...

Page 13: ...the installation s network switch The SITESCAPE application can then be used to search for and add all the COLDSTORE devices on the installation s network to My Site SITESCAPE can then be used to ful...

Page 14: ...in the array it may already have been faulty or may have been handled incorrectly during assembly It is essential that all disks are handled carefully are not dropped or even knocked against hard obje...

Reviews: