Ventus Air Handling Units
3. TRANSPORT AND STORAGE
The VENTUS AHUs from size range VS 21-650 are delivered as fully assembled,
assembled in sections or in packages, placed on closed palettes, containing elements to
be assembled on- site by the Authorized VTS Service. This manual does not contain
instructions and guidelines on assembly of the unit
.
Delivery of AHUs elements, in the closed, properly marked and not broken palettes is
going to belong to customer after signing of consignment note by client representative.
Open of closed palettes by customer before arrival of Authorized VTS Service is connect
with take-over of full responsibility for contents and completeness of delivery.
Right after delivery of the unit check the condition of the package and examine if all
necessary elements have been delivered - according to the attached specification and
consignment note.
Unloading packages with AHU subassemblies, transport of the packages to the assembly
location and transport of AHU blocks and elements to the assembly location should be
carried out using special equipment and qualified staff.
Packages onsite must be stored on hardened, dry and protected against any precipitation
place. Hardened surfaces are understood as flat, leveled and hard surface, which does
not change its properties under influence of atmospheric conditions
Packages containing AHU elements should be stored away from places where operate
mechanical devices (vehicles, cranes and other construction machinery). They should be
stored in places where they will not be subject to any mechanical damages, humidity,
aggressive chemical agents, fluids, dusts and other external agents which may
deteriorate their condition.
Unloading pallets from means of transport and transporting them to the AHU’s assembly site should
be performed with the use of a fork lift or crane.
A possibility of transporting assembled AHUs is determined in Table 2.
Table 2. Possibilities of transporting assembled AHUs.
AHU type
Possible to transport
Impossible to transport
VS 21-75 with a
base frame
supply, exhaust, supply-exhaust AHUs with
the cross-flow heat recuperator, with the
rotary regenerator up to 7 modules long
(2587mm)
AHUs over 7 modules long (2587mm) and
AHUs up to 7 modules supply and exhaust
placed one on another, with cross-flow heat
recuperator, with rotary regenerator where the
top part projects over the bottom one.
VS 100-150 with a
base frame
supply, exhaust, supply-exhaust AHUs with
the cross-flow heat recuperator, with the
rotary regenerator up to 6 modules long
(2221mm)
AHUs over 6 modules long (2221mm) and
AHUs up to 6 modules supply and exhaust
placed one on another, with cross-flow heat
recuperator, with rotary regenerator where the
top part projects over the bottom one.
VS 180 - 650
supply as well as exhaust up to 6 modules long
(2195mm)
supply as well as exhaust AHUs longer than 6
modules (2195mm), supply and exhaust AHUs
placed one on another with the cross-flow
recuperator, with the rotary regenerator