VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
C200
STABILITY TEST
HT45-25'-VLC SERIES
02-16-21C
DATE
SECTION
SUPERSEDES
TITLE
04-23-20B
STABILITY TEST - HT45-25'-VLC SERIES
20906-45
Overview
Venturo follows the guidelines of ANSI B30.5 in defining stability. Generally speaking, a truck is considered stable as long as it is
not on the verge of tipping - i.e. with the truck level, at least one tire on each corner of the truck must remain in contact with the
ground.
It is important to note that nearly every installation is unique and will, therefore, typically require stability testing.
The procedure outlined below follows ANSI's (B30.5 - 5-1.1.1) specified "maximum load rating" of 85% of truck stability.
Testing Procedure
1.
Locate the truck on firm, level ground and set parking brake.
2.
Fully deploy stabilizers, making sure they are firmly in contact with supportive ground; use stabilizer pads as required. The
tires of the truck should remain in full contact with the ground.
3.
Inspect wire rope and other key components of crane (consult owners manual for more information).
4.
Conduct an operational check of all crane functions.
5.
Use a
Test Weight
weighing a
minimum
of
1765 lbs
, (includes load block weight of 51 lbs.) to a
maximum of 2000 lbs
.
6.
Place the VLC system into
Stability Mode
(ref. VLC Manual, INST-30000, page 30005)
7.
Position the boom level and fully retracted
8.
Referring to the Stability Chart (drawing 20907) rotate the crane to a position between 1 and 2 o'clock (truck cab is
facing 12 o'clock) to begin testing.
9.
Use the winch to lift the Test Weight; DO NOT allow the weight to be more than 6" off the ground at any time during
testing (for safety).
10.
Extend the boom slowly, until one of three conditions occur:
1)
the over load system stops the
boom out
function,
2)
the boom reaches full extension or
3)
the vehicle begins to be unstable,
whichever occurs first.
Note: If the
boom reaches full extension (without an overload or unstable condition) the % of Rated Capacity is 100% for the given
ZONE.
11.
Use the formula below to determine the
% of Rated Capacity
for each ZONE on the Stability Chart (ref. page
20907).
12.
Note: The "
Max Stable Reach in inches"
is measured from the
center of rotatio
n
of the crane housing to the
lifting load
hook.
"Max Stable Reach" in inches"
% Rated Capacity =
X 100
302
Example 1)
x 100 =
100
or 100% of Rated Capacity for
the given ZONE
Example 2)
96.35
or 96% (rounded) of Rated Capacity for the given
ZONE
13.
Record the % of Rated Capacity in the appropriate blank (region) on the Crane Stability page (ref. 20907) and decal.
14.
Repeat Steps 7 through 12 for each ZONE on the stability page.
Summary of Contents for HT45KX-25