SECTION
DATE
SUPERSEDES
TITLE
ELECTRIC CRANES
C200
07-30-18X
09-27-17W
CABLE & BATTERY
711105
!! IMPORTANT !!
ADEQUATE WIRING IMPERATIVE FOR PROPER OPERATION
1.
PROPER GROUND PATH - SEE DWG 15660
2.
CURRENT DRAW IS SEVERAL HUNDRED AMPERES -
ADEQUATE WIRE SIZE AND BATTERY CAPACITY IS
ABSOLUTELY ESSENTIAL (SEE CHART BELOW).
MINIMUM WIRE GAUGE AND AUXILIARY BATTERY SIZE
MODEL
CE1500
CE6K
CT2000
CT2003/4/5
DT7K
ET5500MPB
ET5500R
ET6KMPB
ET6KR
ET6K
ET8K
ET10K
ET12K
ET8KX
ET10KX
ET12KX
ET12KXP
ET18K(X)
ET25K(X)
ET30KX
ET36KX
TOTAL LENGTH OF CABLE (FT) *
0-20 21-25 26-30 31-40 41-50 51-60 61-70 71-80
#4
#4
#2
#2
#1
#0
#0
#00
#2
#2
#1
#0
#00
NOT RECOMMENDED
#2
#2
#1
#0
#00
NOT RECOMMENDED
SEE DRAWING 15660 FOR CABLE AND BATTERY
REQUIREMENTS
12 VOLT AUXILIARY
BATTERY REQUIREMENTS
CCA (A) ** RC (MIN) ***
350
100
450
100
550
150
*
INCLUDES GROUND CABLE
**
CCA = COLD CRANKING AMPS AT 0° (F).
***
RC = RESERVE CAPACITY IN MINUTES AT 25 AMPS AND 80° (F).
THE RC RATING IS A MEASURE OF THE PERIOD OF TIME THE BATTERY CAN
SUPPLY A GIVEN CURRENT WITHOUT RECHARGING.
®
VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
Summary of Contents for ET12KXP-16
Page 2: ......
Page 4: ......
Page 5: ...TFDUJPO 100 EFTDSJQUJPO TQFDJGJDBUJPOT 7607100B ...
Page 14: ......
Page 15: ...SECTION 150 SAFETY 8604150 ...
Page 23: ...SECTION 200 INSTALLATION 7607200A ...
Page 30: ......
Page 31: ...SECTION 300 MAINTENANCE SERVICE 7607300A ...
Page 39: ...SECTION 400 PARTS 7607400A ...
Page 63: ......