VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
C200
MAN. OVERRIDE INSTR.
ET PROPORTIONAL CRANES
03-08-19A
DATE
SECTION
SUPERSEDES
TITLE
07-30-18
23775
MANUAL OVERRIDE INSTRUCTIONS
ET PROPRTIONAL SERIES CRANES
! !
R E A D
A L L
I N S T R U C T I O N S
B E F O R E
P E R F O R M I N G
M A N U A L
O V E R R I D E
P R O C E D U R E S
! !
Each valve station incorporates [2] hydraulic ports and [2] coils. Manual
override shafts are located in the center of the coils (see figure 4).
Manual override decals are placed on each crane near the valve assembly.
These decals provide a visual aid that helps the operator determine the function
designations (Reference figure 3 & 5).
3-STATION FUNCTIONS:
RR
=
Rot. Right
RL
=
Rot. Left
BU
=
Boom Up
BD
=
Boom Down
BI
=
Boom In
BO
=
Boom Out
21988
ALWAYS BE SURE TO CHECK HYDRAULIC OIL LEVEL BEFORE PROCEEDING. IT IS RECOMMENDED TO
REMOVE ANY ITEM(S) THAT MAY INTERFERE WITH OPERATING THE CRANE MANUALLY. IF POSSIBLE,
STRAPS AND/OR HARNESSES SHOULD BE REMOVED BEFORE OPERATING A CRANE IN MANUAL OVERRIDE !!
4
5
6
Procedure:
1.
Turn Master disconnect switch to "ON"
2.
Remove Protective cap (see figure 1)
3.
Rotate Valve Stem Clockwise to close (see figure 2)
4.
Power up the pendant / radio
4.1.
Twist EMERGENCY STOP button clockwise
5.
On the crane, reference the function you wish to perform using the manual override decal (see
figure 3)
6.
Using a tool with a diameter of 1/8" or smaller, press the shaft inward and hold
7.
Reference the functions listed on your pendant or radio (see figure 6)
8.
Press the switch or button for the same function
9.
If you need to change function,
9.1.
Release switch or button
9.2.
Remove tool from shaft
9.3.
Go to step 5
For assistance, please feel free to contact Technical Support at 800-226-2238.
COIL
PORT
SHAFT
PROPORTIONAL COIL: MANUAL
OVERRIDE WITH GUARD
1
2
3
UP
OUT
UP
RIGHT
DOWN
IN
DOWN
LEFT
EXTENSION
WINCH
ELEVATION
ROTATION
P O
W E R
E
M
E
R
G
E N C Y
S
T
O
P
HORN
UP
OUT
UP
RIGHT
DOWN
IN
DOWN
LEFT
BOOM
WINCH
BOOM
ROTATE
HORN
S
T
N
E
P
O
Y
C
G
R
E
M
E
P
O
T
S
Y
C
N
E
G
R
E
M
E
BATT
POWER
22158
ET 12
25C 000001
Protective Cap
OVERRIDE
NORMAL
PROPORTIONAL
VALVE
ROT AT E ST EM
KEEP VALVE IN NORMAL POSITION.
OVERRIDE POSITION IS INTENDED
FOR EMERGENCY USE ONLY.
WARNING!
1
9
3
1
5
-2
R
e
v
B
MODEL NO.
OVERRIDE
NORMAL
PROPORTIONAL
VALVE
ROTATE STEM
KEEP VALVE IN NORMAL POSITION.
OVERRIDE POSITION IS INTENDED
FOR EMERGENCY USE ONLY.
WARNING!
1
9
3
1
5
-2
R
e
v
B
MODEL NO.
BI
BU
RR
MANUAL
OVERRIDE
23421
BI
BU
R
R
M
AN
U
AL
O
VE
R
R
ID
E
2
3
4
2
1
Summary of Contents for ET12KP-16
Page 2: ......
Page 4: ......
Page 5: ...TFDUJPO 100 EFTDSJQUJPO TQFDJGJDBUJPOT 7607100B...
Page 14: ......
Page 15: ...SECTION 150 SAFETY 8604150...
Page 23: ...SECTION 200 INSTALLATION 7607200A...
Page 30: ......
Page 31: ...SECTION 300 MAINTENANCE SERVICE 7607300A...
Page 39: ...SECTION 400 PARTS 7607400A...
Page 63: ......