11
VUE2 150 P ЕС Comfo
Fig. 7. Panel display in the OFF mode
When the unit is off (Fig. 7) the control panel display indicates:
Room temperature;
Day;
Time;
Deactivated status .
2. Unit Ventilation Mode Selection
The unit fan speed can be set in several ways:
From the control panel: Press the
button to increase the speed or press the
button to reduce the speed cyclically (i.e. speed
1 - speed 2 - speed 3);
From the remote controller: Press the
button to increase the speed or press the
button to reduce the speed cyclically
(i.e. speed 1 - speed 2 - speed 3);
From the remote controller: Press the
button to select speed 1, press the
to select speed 2 or press the
button to
select speed 3 correspondingly.
The control panel display shows the current fan speed status:
Indicator
— «Speed 1» mode;
Indicator
— «Speed 2» mode;
Indicator
— «Speed 3» mode.
Рис. 8. Дисплей во включенном состоянии
When the unit is on (Fig. 8) the control panel display indicates:
Room temperature;
Day;
Time;
Fan speed status
;
Timer status;
•
Timer operation is shown by the
indicator.
•
When the timer is switched off the
indicator goes on.
3. Timer.
The timer enables automatic switching of the fans to the maximum speed with automatic reset after a set period of time in the range from
20 to 60 minutes.
The timer can be activated / deactivated:
From the control panel: to activate the timer press and hold the
button and then press the
button. A single press of the
button sets the timer to 20 minutes while each subsequent press increases the timer setting in 10 minute increments. The maximum timer
value is 60 minutes. To deactivate the timer press and hold the
button for 3 seconds;
From the remote controller: to activate the timer for 20 minutes press the
button. To deactivate the timer switch the unit off
by means of the
button.
4. Heat Exchanger Freezing Protection.
If the exhaust air temperature downstream of the heat exchanger falls below +3 °C the supply fan shuts down. When the air temperature
rises above the +3 °С threshold, the unit reverts to rated operation.