background image

6

VKP/VKPI/VKPF/VKPFI

www.ventilation-system.com

TECHNICAL DATA

The unit is designed for indoor application with the ambient temperature ranging from 0 °C  up +45 °C and relative humidity up to 80 %. 
The unit is rated as a Class I electrical appliance.
The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.

VKP/VKPI

2E 400х200  

2E 500х250

4E 500х300

4D 500х300

Voltage [V] 

1~ 220-240

1~ 220-240

1~ 220-240

3~ 400

Frequency [Hz] 

50

60

50

60

50

60

50

60

Power [W] 

138

200

305

380

140

175

136

165

Current [A] 

0.60

0.88

1.32

1.65

0.57

0.73

0.34

0.53

Maximum air flow [m

3

/h] 

930

1070

1720

1850

1700

1855

1380

1620

RPM [min

-1

2600

2850

2550

2830

1390

1530

1360

1600

Sound pressure level at 3 m distance 

[dBA]

69/61*

71/63*

76/65*

78/67*

53/45*

55/46*

53/45*

55/46*

Transported air temperature [°С] -25...+45

-25...+45

-25...+45

-25...+45

-25...+45

-25...+50

-25...+65

-25...+55

Ingress protection rating of the unit 

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

Electric motor IP rating 

IP44

IP44

IP44

IP44

IP54

IP54

IP54

IP54

VKP/VKPI

4E 600х300

4D 600х300

4E 600х350  

Voltage [V] 

1~ 220-240

3~ 400

1~ 220-240

Frequency [Hz] 

50

60

50

60

50

60

Power [W] 

220

310

230

235

470

700

Current [A] 

0.9

1.38

0.52

0.53

2.37

3.15

Maximum air flow [m

3

/h] 

2470

2510

2530

2630

2950

3515

RPM [min

-1

1400

1450

1360

1600

1370

1460

Sound pressure level at 3 m distance 

[dBA]

55/47*

55/57*

53/46*

53/46*

67/59*

68/59*

Transported air temperature [°С]

-25...+45

-25...+45

-25...+70

-25...+65

-40...+80

-40...+55

Ingress protection rating of the unit 

IPX4

IPX4

IPX4

IPX4

IPX4

IPX4

Electric motor IP rating 

IP54

IP54

IP54

IP54

IP54

IP54

VKP/VKPI

4D 600х350

4D 1000х500  

Voltage [V] 

3~ 400 Δ

3~ 400 Y

3~ 400 

Frequency [Hz] 

50

60

50

60

50

Power [W] 

510

750

380

515

3800

Current [A] 

1.41

1.44

0.7

0.93

6.6

Maximum air flow [m

3

/h] 

2970

3410

2660

2730

15000

RPM [min

-1

1415

1610

1235

1220

1360

Sound pressure level at 3 m distance 

[dBA]

64/55*

64/55*

63/55*

63/55*

70

Transported air temperature [°С]

-40...+60

-40...+60

-40...+80

-40...+40

-25...+40

Ingress protection rating of the unit 

IPX4

IPX4

IPX4

IPX4

IPX4

Electric motor IP rating 

IP54

IP54

IP54

IP54

IP54

* Parameters for a VKPI model.

Summary of Contents for VKPF

Page 1: ...Duct rectangular fan USER S MANUAL VKP VKPI VKPF VKPFI...

Page 2: ...ractical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of th...

Page 3: ...ed Do not expose the device to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in...

Page 4: ...ed it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a safety hazard Ensure that the appliance is switched off from the supply mains before rem...

Page 5: ...PRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORISED ACCESS B...

Page 6: ...X4 IPX4 IPX4 IPX4 IPX4 Electric motor IP rating IP44 IP44 IP44 IP44 IP54 IP54 IP54 IP54 VKP VKPI 4E 600 300 4D 600 300 4E 600 350 Voltage V 1 220 240 3 400 1 220 240 Frequency Hz 50 60 50 60 50 60 Pow...

Page 7: ...0 735 36 38 VKP 4D 600 350 600 620 640 350 370 390 390 735 36 38 Model Dimensions mm Weight kg B B1 B2 H H1 H2 H3 L VKP 4D 1000 500 1000 1020 1040 500 520 540 720 1150 126 0 Model Dimensions mm Weight...

Page 8: ...303 Current A 0 67 3 10 1 70 1 59 0 8 Maximum air flow m3 h 1490 2350 2350 1550 1620 RPM min 1 930 1230 1300 890 910 Sound pressure level at 3 m distance dBA 45 38 57 47 56 47 47 39 51 41 Transported...

Page 9: ...25 40 Ingress protection rating of the unit IPX4 IPX4 IPX4 IPX4 Electric motor IP rating IP54 IP54 IP54 IP54 VKPF VKPFI 6D 700 400 4D 800 500 6D 800 500 8D 800 500 Unit voltage V 50 60 Hz 3 400 3 400...

Page 10: ...300 320 340 375 680 35 VKPF 4D 600 300 600 620 640 300 320 340 375 680 35 VKPF 6E 600 300 600 620 640 300 320 340 375 680 35 VKPF 6D 600 300 600 620 640 300 320 340 375 680 35 VKPF 4E 600 350 600 620...

Page 11: ...0 300 600 620 640 670 300 320 340 480 680 56 VKPFI 4D 600 300 600 620 640 670 300 320 340 480 680 56 VKPFI 6E 600 300 600 620 640 670 300 320 340 480 680 56 VKPFI 6D 600 300 600 620 640 670 300 320 34...

Page 12: ...hat the arrow on the fan casing matches the air flow direction in the system The fan should always be installed on its own hangers so that it does not load the flexible connectors and the connected ai...

Page 13: ...ference only The actual conductor cross section selection must be based on its type the maximum permissible heating insulation length and installation method in the air pipes or inside walls The recom...

Page 14: ...n VKP VKPI 4D 600 300 units with a three phase motor Wiring diagram for VKP VKPI 4D 600 350 units with a three phase motor 400 V 50 60 Hz L N X1 1 2 3 N L QF PE 230 50 60 4 PE L2 L1 QF PE 400 50 60 L2...

Page 15: ...y set The TW1 TW2 TK1 TK2 are the electrical leads of the normally closed contact of the motor overheating protection Connect the contact in series to power circuit of the magnetic starter coil KM1 th...

Page 16: ...or current regulate the torque Regulation by limiting the current sets the maximum in rush current equal to 300 400 or 250 in some rare instances of the rated current and reduces torque characteristic...

Page 17: ...or protection system less sensitive As a result the switching equipment will not be able to detect motor overload in time due to a high current sensing threshold Such problems as mentioned above can o...

Page 18: ...18 VKP VKPI VKPF VKPFI www ventilation system com 1 3 4 5 6 2...

Page 19: ...andling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechani...

Page 20: ...ct the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual i...

Page 21: ...STALLATION CERTIFICATE The VKP _____________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Page 22: ...22 VKP VKPI VKPF VKPFI www ventilation system com...

Page 23: ...23 www ventilation system com VKP VKPI VKPF VKPFI...

Page 24: ...V07EN 04...

Reviews: