SAFETY REQUIREMENTS

UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS

•  Disconnect the unit from power mains prior 

to any installation operations.

•  Unpack the unit with care.

•  The unit must be grounded!

•  While installing the unit, follow the safety 

regulations specific to the use of electric 
tools.

•  Please read the user’s manual carefully prior to installing and operating the unit.
•  All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical 

norms and standards must be observed when installing and operating the unit.

•  The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.
•  Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.
•  After a careful reading of the manual, keep it for the entire service life of the unit.
•  While transferring the unit control, the user’s manual must be turned over to the receiving operator.

CONTENTS

Safety requirements ..................................................................................................................................................................... 2
Purpose ................................................................................................................................................................................................ 4
Delivery set ........................................................................................................................................................................................ 4
Designation key .............................................................................................................................................................................. 4
Technical data .................................................................................................................................................................................. 5
Design and operating principle ........................................................................................................................................... 7
Installation and set-up................................................................................................................................................................ 8
Connection to power mains .................................................................................................................................................. 10
Technical maintenance .............................................................................................................................................................. 12
Troubleshooting ............................................................................................................................................................................. 13
Storage and transportation regulations .......................................................................................................................... 13
Manufacturer’s warranty ........................................................................................................................................................... 14
Certificate of acceptance .......................................................................................................................................................... 15
Seller information .......................................................................................................................................................................... 15
Installation certificate .................................................................................................................................................................. 15
Warranty card ................................................................................................................................................................................... 15

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the KSK unit and all its 
modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
The information in this user’s manual is correct at the time of the document’s preparation.  
The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to 
incorporate the latest technological developments.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any information 
search system or translated into any language in any form without the prior written permission of the Company.

Summary of Contents for KSK 150 4D

Page 1: ...KSK Centrifugal fan in sound insulated casing USER S MANUAL...

Page 2: ...5 Design and operating principle 7 Installation and set up 8 Connection to power mains 10 Technical maintenance 12 Troubleshooting 13 Storage and transportation regulations 13 Manufacturer s warranty...

Page 3: ...electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or hig...

Page 4: ...APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN PURPOSE The centrifugal fan in a sound insulated casing is designed for supply an...

Page 5: ...30 5 33 40 0 KSK 250 4D 250 575 435 665 505 700 675 645 620 285 282 5 330 5 33 40 0 KSK 315 4E 315 690 550 708 600 715 700 650 612 327 329 390 59 53 0 KSK 315 4D 315 690 550 708 600 715 700 650 612 32...

Page 6: ...710 5290 4695 5345 RPM min 1488 1776 1475 1750 3025 3328 3125 3384 Sound pressure level at a distance of 3 m dBA 46 48 46 47 52 54 53 55 Transported air temperature C 20 120 Ingress protection rating...

Page 7: ...intly balanced statically and dynamically The high performance single phase or three phase electric motor with a squirrel cage rotor is completely maintenance free The power is adjusted by means of tr...

Page 8: ...a direct air duct section of at least one air duct diameter long on the inlet side and at least three air duct diameters long on the outlet side The fan is not a ready to use unit and requires connect...

Page 9: ...nting brackets Model Distances for marking mm H2 B1 B2 H3 KSK 150 170 330 193 276 KSK 160 170 330 193 276 KSK 200 220 365 216 5 309 5 KSK 250 270 435 260 5 355 5 KSK 315 300 550 320 448 KSK 355 300 60...

Page 10: ...E RATED ELECTRICAL PARAMETERS OF THE UNIT ARE SHOWN ON THE RATING PLATE The unit is rated for connection to to 1 230 V 50 60 Hz or 3 400 V 50 Hz power mains The unit must be connected to power mains u...

Page 11: ...an casing as shown in the wiring diagram The wiring diagram sticker is located inside the motor terminal box CAUTION Make sure that the fan impeller wheel rotates in the direction of the arrow applied...

Page 12: ...cloth or a brush dampened with water and mild detergent solution Remove dust from soundproof surface using a vacuum cleaner Check screw connections as well as rivet and welded joints Check tightness...

Page 13: ...ode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling during l...

Page 14: ...es not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismo...

Page 15: ...er s manual The warranty terms are acknowledged and accepted Customer s Signature The KSK unit has been connected to power mains pursuant to the requirements stated in the present user s manual Instal...

Page 16: ...V72EN 06...

Reviews: