MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby 
declare that the product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/
EU and CE-marking Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance 
of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation 
through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the 
manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults 
in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means 
of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include: 

•  routine technical maintenance
•  unit installation/dismantling 
•  unit setup

To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment 
paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty 
service. 

The manufacturer’s warranty does not apply to the following cases:

•  User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing 

component parts previously dismounted by the user.

•  Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual.
•  User’s failure to ensure timely technical maintenance of the unit.
•  External damage to the unit casing (excluding external modifications as required for installation) and internal components caused 

by the user.

•  Redesign or engineering changes to the unit.
•  Replacement and use of any assemblies, parts and components not approved by the manufacturer.
•  Unit misuse.
•  Violation of the unit installation regulations by the user.
•  Violation of the unit control regulations by the user.
•  Unit connection to power mains with a voltage different from the one stated in the user's manual.
•  Unit breakdown due to voltage surges in power mains.
•  Discretionary repair of the unit by the user.
•  Unit repair by any persons without the manufacturer’s authorization.
•  Expiration of the unit warranty period.
•  Violation of the unit transportation regulations by the user.
•  Violation of the unit storage regulations by the user.
•  Wrongful actions against the unit committed by third parties.
•  Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
•  Missing seals if provided by the user’s manual.
•  Failure to submit the user’s manual with the unit purchase date stamp.
•  Missing payment paperwork certifying the unit purchase.

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND 

TROUBLE-FREE OPERATION OF THE UNIT.

USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON 

PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL 

WITH THE PURCHASE DATE STAMP.

Summary of Contents for KSK 150 4D

Page 1: ...KSK Centrifugal fan in sound insulated casing USER S MANUAL...

Page 2: ...5 Design and operating principle 7 Installation and set up 8 Connection to power mains 10 Technical maintenance 12 Troubleshooting 13 Storage and transportation regulations 13 Manufacturer s warranty...

Page 3: ...electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or hig...

Page 4: ...APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN PURPOSE The centrifugal fan in a sound insulated casing is designed for supply an...

Page 5: ...30 5 33 40 0 KSK 250 4D 250 575 435 665 505 700 675 645 620 285 282 5 330 5 33 40 0 KSK 315 4E 315 690 550 708 600 715 700 650 612 327 329 390 59 53 0 KSK 315 4D 315 690 550 708 600 715 700 650 612 32...

Page 6: ...710 5290 4695 5345 RPM min 1488 1776 1475 1750 3025 3328 3125 3384 Sound pressure level at a distance of 3 m dBA 46 48 46 47 52 54 53 55 Transported air temperature C 20 120 Ingress protection rating...

Page 7: ...intly balanced statically and dynamically The high performance single phase or three phase electric motor with a squirrel cage rotor is completely maintenance free The power is adjusted by means of tr...

Page 8: ...a direct air duct section of at least one air duct diameter long on the inlet side and at least three air duct diameters long on the outlet side The fan is not a ready to use unit and requires connect...

Page 9: ...nting brackets Model Distances for marking mm H2 B1 B2 H3 KSK 150 170 330 193 276 KSK 160 170 330 193 276 KSK 200 220 365 216 5 309 5 KSK 250 270 435 260 5 355 5 KSK 315 300 550 320 448 KSK 355 300 60...

Page 10: ...E RATED ELECTRICAL PARAMETERS OF THE UNIT ARE SHOWN ON THE RATING PLATE The unit is rated for connection to to 1 230 V 50 60 Hz or 3 400 V 50 Hz power mains The unit must be connected to power mains u...

Page 11: ...an casing as shown in the wiring diagram The wiring diagram sticker is located inside the motor terminal box CAUTION Make sure that the fan impeller wheel rotates in the direction of the arrow applied...

Page 12: ...cloth or a brush dampened with water and mild detergent solution Remove dust from soundproof surface using a vacuum cleaner Check screw connections as well as rivet and welded joints Check tightness...

Page 13: ...ode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling during l...

Page 14: ...es not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismo...

Page 15: ...er s manual The warranty terms are acknowledged and accepted Customer s Signature The KSK unit has been connected to power mains pursuant to the requirements stated in the present user s manual Instal...

Page 16: ...V72EN 06...

Reviews: