•  Do not change the power cable length at 

your own discretion. Do not bend the power 
cable. Avoid damaging the power cable. Do 
not put any foreign objects on the power 
cable.

•  Do not lay the power cable of the unit in 

close proximity to heating equipment.

•  Do not use damaged equipment or cables 

when connecting the unit to power mains.

•  Do not operate the unit outside the 

temperature range stated in the user’s 
manual. Do not operate the unit in 
aggressive or explosive environments.

•  Do not touch the unit controls with wet 

hands. Do not carry out the installation and 
maintenance operations with wet hands.

•  Do not wash the unit with water. Protect the 

electric parts of the unit against ingress of 
water. 

•  Do not allow children to operate the unit.

•  Disconnect the unit from power mains prior 

to any technical  maintenance.

•  Do not store any explosive or highly 

flammable substances in close proximity to 
the unit.

•  When the unit generates unusual sounds, 

odour, or emits smoke, disconnect it from 
power supply and contact the Seller.

•  Do not open the unit during operation.

•  Do not direct the air flow produced by the 

unit towards open flame or ignition sources.

•  Do not block the air duct when the unit is 

switched on.

•  In case of continuous operation of the unit, 

periodically check the security of mounting.

•  Do not sit on the unit and avoid placing 

foreign objects on it.

•  Use the unit only for its intended purpose.

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE THE UNIT AS UNSORTED MUNICIPAL WASTE.

Summary of Contents for KSK 150 4D

Page 1: ...KSK Centrifugal fan in sound insulated casing USER S MANUAL...

Page 2: ...5 Design and operating principle 7 Installation and set up 8 Connection to power mains 10 Technical maintenance 12 Troubleshooting 13 Storage and transportation regulations 13 Manufacturer s warranty...

Page 3: ...electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or hig...

Page 4: ...APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN PURPOSE The centrifugal fan in a sound insulated casing is designed for supply an...

Page 5: ...30 5 33 40 0 KSK 250 4D 250 575 435 665 505 700 675 645 620 285 282 5 330 5 33 40 0 KSK 315 4E 315 690 550 708 600 715 700 650 612 327 329 390 59 53 0 KSK 315 4D 315 690 550 708 600 715 700 650 612 32...

Page 6: ...710 5290 4695 5345 RPM min 1488 1776 1475 1750 3025 3328 3125 3384 Sound pressure level at a distance of 3 m dBA 46 48 46 47 52 54 53 55 Transported air temperature C 20 120 Ingress protection rating...

Page 7: ...intly balanced statically and dynamically The high performance single phase or three phase electric motor with a squirrel cage rotor is completely maintenance free The power is adjusted by means of tr...

Page 8: ...a direct air duct section of at least one air duct diameter long on the inlet side and at least three air duct diameters long on the outlet side The fan is not a ready to use unit and requires connect...

Page 9: ...nting brackets Model Distances for marking mm H2 B1 B2 H3 KSK 150 170 330 193 276 KSK 160 170 330 193 276 KSK 200 220 365 216 5 309 5 KSK 250 270 435 260 5 355 5 KSK 315 300 550 320 448 KSK 355 300 60...

Page 10: ...E RATED ELECTRICAL PARAMETERS OF THE UNIT ARE SHOWN ON THE RATING PLATE The unit is rated for connection to to 1 230 V 50 60 Hz or 3 400 V 50 Hz power mains The unit must be connected to power mains u...

Page 11: ...an casing as shown in the wiring diagram The wiring diagram sticker is located inside the motor terminal box CAUTION Make sure that the fan impeller wheel rotates in the direction of the arrow applied...

Page 12: ...cloth or a brush dampened with water and mild detergent solution Remove dust from soundproof surface using a vacuum cleaner Check screw connections as well as rivet and welded joints Check tightness...

Page 13: ...ode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling during l...

Page 14: ...es not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismo...

Page 15: ...er s manual The warranty terms are acknowledged and accepted Customer s Signature The KSK unit has been connected to power mains pursuant to the requirements stated in the present user s manual Instal...

Page 16: ...V72EN 06...

Reviews: