background image

8

КН-1

www.ventilation-system.com

TECHNICAL MAINTENANCE

Maintenance operations of the unit are required twice per month.  They include general cleaning of the unit and the following operations:

1. Filter maintenance.

To remove the filter cartridge press on the front latches. 
Remove the filter and the fabric insert by releasing the detent.  Wash the filter in a warm detergent solution.  Alternatively put the filter in 
a dishwasher.  The internal fan should be cleaned at least every 12 months.  Wipe the exhaust hood internals with a wet cloth soaked in 
washing-up liquid solution.  Replace the filter and press it upwards until it clicks locked. 

2. Light bulb replacement.

Remove the lens by pressing on the clips in the direction of the arrow and replace the light bulb.

Summary of Contents for KH-1

Page 1: ...КН 1 Kitchen hood USER S MANUAL ...

Page 2: ...NTS Purpose 3 Overall dimension 3 Installation 3 Air flow control 4 Connection to power mains 7 Technical maintenance 8 Manufacturer s warranty 9 Certificate of acceptance 10 Seller information 10 Installation certificate 10 Warranty card 10 ...

Page 3: ...n exhaust hood is designed for installation into ventilation systems of small and medium sized spaces OVERALL DIMENSION INSTALLATION Ø125 598 299 383 9 5 16 50 22 13 190 511 480 159 233 40 80 70 min 400 650 TECHNICAL DATA Width 60 cm Electrical connection 230 V Lighting 11 W edge lighted panel A B C D The mounting accessories and screws are included with the unit Flange connector installation Moun...

Page 4: ...stem connection The exhaust hood is connected by means of a Ø125 mm air duct A B Warning When using flexible air ducts ensure a tight connection with the flange and avoid excessive bending AIR FLOW CONTROL The air flow is controlled by means of regulator B of damping valve A Set up the valve as necessary use the main ventilation balancing diagram see Page 6 to achieve an optimum balance ...

Page 5: ...r for supply air flow control The cutting marks are applied to the damper in accordance with the supply air balancing diagram see Page 6 When re installing the damper make sure that guide D is properly mounted in place The pressure differential is measured via bleed pipe at measuring point E upstream of the union joint ...

Page 6: ...Pa LpA sound pressure level at 10 m2 Lwa sound power level kW 700 600 500 400 300 200 100 90 80 70 60 50 45 40 35 30 25 20 10 20 30 40 50 60 70 80 90 100 150 200 Static air pressure drop Pa Air flow l s Lpa 45 Lwa 49 Lpa 40 Lwa 44 Lpa 30 Lwa 34 Lpa 25 Lwa 29 Lpa 35 Lwa 39 Throttle flap opening Enlarged opening Without throttle flap 1 2 3 4 5 LpA sound pressure level at 10 m2 Lwa sound power level ...

Page 7: ...ect the kitchen exhaust hood to an air handling unit controller or a fan according to the schematic diagram below The cable extends from the upper section of the exhaust hood Grey Black Yellow green Blue Brown P2 Kitchen hood TS1 1 2 1 2 L1 PE DEACTIVATION FUNCTIONS The exhaust hood casing has the following controls A damper handle B light button Open the damper while cooking The damper closes aut...

Page 8: ...the filter and the fabric insert by releasing the detent Wash the filter in a warm detergent solution Alternatively put the filter in a dishwasher The internal fan should be cleaned at least every 12 months Wipe the exhaust hood internals with a wet cloth soaked in washing up liquid solution Replace the filter and press it upwards until it clicks locked 2 Light bulb replacement Remove the lens by ...

Page 9: ...s not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of the u...

Page 10: ...uality Inspector s Stamp The KH 1 unit has been connected to power mains pursuant to the requirements stated in the present user s manual Installation Company Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical co...

Page 11: ...11 www ventilation system com ...

Page 12: ...V169EN 01 ...

Reviews: