www.vents-us.com
10
3. Remove the mounting plate to enable access to the control board and connection of the ventilator to power supply and connection of other ventilators
as stated in
Unit connection
, page 10.
To enable access to the control board in the mounting plate remove the four fixing screws. Then disconnect the mounting plate from its fame with care
and push it aside to enable access to the control board. While doing that avoid abrupt movements not to damage the connecting cables between the
control board and the mounting plate. Disconnect the mounting plate from the ventilation unit by disconnecting the two connectors.
Re-assemble the mounting plate in the reverse order. Install the cables with care.
4. Install the mounting plate unit using the supplied cardboard mounting template and expansion anchors.
Lean the mounting template
against the wall and mark four
holes for expansion anchors
as well as holes for routing the
cable.
Take off the mounting template,
drill the holes and insert the
expansion anchors.
Lean the mounting plate unit
against the wall and screw it
to the wall.
5. Install the air flow rectifier, the filter, the ceramic regenerator, one more filter and one more air flow rectifier inside the telescopic air duct.
Ventilation unit
Filter
Air flow rectifier
Air flow rectifier
Ceramic regenerator
Filter