GENERAL OPERATION
Operation - 42
Starting below
SLOPE
SLOPE
0
°
SLOPE
0
°
SLOPE
0
°
SLOPE
0
°
Hold
Up Swipe
SLOPE
0
°
Up Swipe
the sensor area,
swipe your thumb
up across the
sensor to scroll
through options
such as the
audible or visual
alert set-points or
the display screen
options.
Tips for Selecting and Swiping
•
Do not try to hold (select) or swipe while wearing
gloves.
• After making a selection or swiping, move your
hand away from the gauge before repeating.
Swiping to fast or hovering your hand above the
sensor area can cause unintentional input.
• If the sensor is not capturing your swipe move-
ments, try increasing or decreasing the distance
from the surface of the gauge, slowing down your
motion, or using your entire hand instead of just
your thumb.
Startup
Every time the
Alarm
Enabled
Alarm
Muted
power unit is started,
the slope gauge will
display a Ventrac
splash screen, fol-
lowed by the current
set-points for the
audible and visual alerts. The startup screen will also
show whether the audible alarm is turned on (en
-
abled) or muted.
After displaying the startup screen, the slope gauge
will return to the last selected display screen and dis-
play the current slope.
Menu Options
To calibrate the slope gauge, change audible or visual
alert set-points, or to change the display screen, hold
your thumb over the slope gauge sensor for eight
seconds to enter the options menu. The option
screens
A
will display instructions for making changes
to the current feature. Swipe up across
the sensor to cycle through the menu
screens. Each swipe advances one
position to the next menu screen. The
dots (A) at the top of the screen allow
the user to see their screen position
(highlighted dot) in the menu.
Menu Screen 1
allows the user to
mute or enable the audible alarm. The
screen will display the current state of
the alarm. Hold over the sensor for three
seconds to change the setting.
Menu Screen 2
changes the audible
alarm set-point. Hold over the sensor until the set-
point angle begins to flash. Swipe up across the sen
-
sor to cycle through the set-point options.
Flashing
When the desired set-point is reached, hold over the
sensor to save the setting.
Menu Screen 3
changes the visual alarm set-point.
Hold over the sensor until the set-point angle begins
to flash. Swipe up across the sensor to cycle through
the set-point options.
Flashing
When the desired set-point is reached, hold over the
sensor to save the setting.
Menu Screen 4
calibrates the slope gauge. This zeros
out the gauge at the current position. Refer to the
slope gauge calibration section for calibration instruc-
tions.
Menu Screen 5
changes the screen display. There are
five screen display options from which the operator
can choose to display during operation. Hold over the
sensor until the factory default screen is displayed.
Swipe up to cycle through the display screen options.
https://www.tractormanualpdf.info/