background image

The following options are usually set by the installer. Changing 

these options could cause your fan not to operate correctly.

NUMBER OF FAN SPEEDS

The number of fan speeds selected is dependent on the 
type of fan installed - 1-Speed, 2-Speed or 3-Speed fan. 
Factory set to a 2-speed fan.

H

SPEED

HIGH SPEED START

For some installations, a low speed start may not be 
adequate to fully open the damper doors. When this 
option is set to ON and starting the fan in low speed, the 
fan will start in high speed to open the damper doors 
and after about 10 seconds will return to the low speed 
setting. Default is Off.

OFF

Access Options- Press and hold the  
MODE  key to display the options.

Press the MODE key until Speed is 
displayed.

Press the          or          key to 
change the number of speeds. The 
change is saved when the backlight 
turns off.

Access Options- Press and hold the  
MODE  key to display the options.

Press the MODE key until HSS is 
displayed.

Press the          key to turn the 
option on or the          key to turn 
the option off. The change is saved 
when the backlight turns off.

L

OPTIONS

OUTDOOR TEMPERATURE LIMIT

SAFETY TIMER HOURS

The built in safety timer runs in the background in 
Temperature Mode and automatically turns the fan off after 
8 hours in case you forget. Default is 8 hours. Adjustable 
from 1 to 12 hours. The Safety Timer can be turned Off 
although not recommended.

Only displayed if the optional TS3J Outdoor Temperature 
Sensor is installed (see page 4 for more information on 
the TS3J sensor). Fan operation will be delayed in both 
Timer and Temperature Mode until the outdoor 
temperature drops below the limit set. Default limit is 

o

o

o

80 . Adjustable from 60  to 99 . LIMIT will be displayed 
when operation is inhibited because the outdoor 
temperature limit is too high.

Outdoor

Limit

STimer

Access Options- Press and hold the  
MODE  key to display the options. 

Press the          or          key to 
change the outdoor temperature 
limit. The change is saved when 
the backlight turns off.

Access Options- Press and hold the  
MODE  key to display the options.

If STimer is not displayed, press the 
MODE key until STimer is displayed.

Press and hold the          or          key 
to adjust the safety timer hours. The 
change is saved when the backlight 
turns off.

HOMEOWNER SECTION

page 4 of 8

P/N 780104502 2/20 Rev B

Summary of Contents for WTT

Page 1: ...ome and connects to the FC3JF already installed on the VentCool whole house fan using a plug play cable included COMPONENTS 1 VentCool WTT Whole House Fan Wall Control WTT p n 580011702 1 VentCool Fan...

Page 2: ...ture that you want the house to cool to Temperature control display Display 1 2 3 4 1 2 3 1 2 3 Before operating your whole house fan be sure to open windows and close fireplace dampers Refer to your...

Page 3: ...t temperature operation The fan will turn on when the Set To temperature is below the Indoor temperature Once the Indoor temperature drops below the Set To temperature the fan will turn off If the Ind...

Page 4: ...backlight turns off L OPTIONS OUTDOOR TEMPERATURE LIMIT SAFETY TIMER HOURS The built in safety timer runs in the background in Temperature Mode and automatically turns the fan off after 8 hours in cas...

Page 5: ...stalled on the junction box on the fan Step 2 Connect Cable to the FC3JF Feed this end to the gang box Insert into FC3JF already installed on fan The WTT is installed in the upstairs sleeping space In...

Page 6: ...mper doors and after about 10 seconds will return to the low speed setting Default is Off OFF Access Options Press and hold the MODE key to display the first option Press the MODE key until HSS is dis...

Page 7: ...is a few degrees lower than the Indoor temperature On will blink when the fan is running The display indicates On but the fan is not running If On is blinking but the fan is not running check the wir...

Page 8: ...Remote Control Replacement WLM wireless plug in module Replacement RTT wireless remote control Cable 50 FT PNP50 VentCool WiFi Control Upgrade Kit Includes WLM WiFi Plug In Module This manual may be...