Vent-Axia Lo-Carbon VA100 SELV LHTP Installation And Wiring Instructions Download Page 3

Installation and Wiring Instructions for the VA100 Lo-Carbon SELV Range of 
Extractor Fans. 

  IMPORTANT: 
  READ THESE INSTRUCTIONS 
  BEFORE COMMENCING THE  
  INSTALLATION 

 

DO NOT install this product in areas where the following may be present or occur: 

  Excessive oil or a grease laden atmosphere. 

  Corrosive or flammable gases, liquids or vapours. 

• 

Ambient temperatures higher than 40°C or less than –5°C. 

• 

Possible obstructions which would hinder the access or removal of the Fan. 

 

SAFETY AND GUIDANCE NOTES 
A. 

All wiring to be in accordance with the current I.E.E. Regulations, or the 
appropriate standards of your country and 

MUST 

be installed by a suitably 

qualified person. 

B. 

The Fan should be provided with a local isolator switch capable of disconnecting 
all poles, having a contact separation of at least 3mm. 

C. 

Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the 
rating label. 

D. 

The Fan should only be used in conjunction with the appropriate Vent-Axia 
products. 

E. 

The fan should only be used in conjunction with fixed wiring. 

F. 

When the Fan is used to remove air from a room containing a fuel-burning 
appliance, ensure that the air replacement is adequate for both the fan and the 
fuel-burning appliance. 

G. 

 The Fan should not be used where it is liable to be subject to direct water spray 

for prolonged periods of time. 

H. 

Where ducted Fans are used to handle moisture-laden air, a condensation trap 
should be fitted. Horizontal ducts should be arranged to slope slightly downwards 
away from the Fan. 

I. 

This appliance is not intended for use by persons (including children) with 
reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety. 

J. 

Children should be supervised to ensure that they do not play with the appliance. 

K. 

Stationary appliances not fitted with means for disconnection from the supply 
mains having a contact separation in all poles that provide full disconnection 
under over voltage category III, the instructions state that means for 
disconnection must be incorporated in the fixed wiring in accordance with the 
wiring rules. 

 

IMPORTANT:- ONLY CONNECT TOGETHER PRODUCTS FROM THE VA100 LO-
CARBON SELV RANGE SINCE THE FANS ARE SPECIALLY DESIGNED TO WORK 
ON 12V DC AND ARE NOT COMPATIBLE WITH OTHER VENT-AXIA 
CONTROLLERS. DO NOT CONNECT MORE THAN ONE FAN TO THE 
CONTROLLER. 

Summary of Contents for Lo-Carbon VA100 SELV LHTP

Page 1: ...0 49A XP 44 16 15A LT 45 90 50A XT 44 16 16A LHTP 43 60 64A XHTP PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS VA100 Lo Carbon SELV RANGE IPX7 FAN UNITS 12V...

Page 2: ......

Page 3: ...nsure that the air replacement is adequate for both the fan and the fuel burning appliance G The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of...

Page 4: ...cubicle or enclosure It must be sited away from direct sources of water spray and out of reach 1 5m of a person using a fixed bath or shower 2 Site away from direct sources of heat Ambient temperature...

Page 5: ...diameter hole in the glass 2 Fit spacers as required behind the fan back plate engaging the locating pips in the corner holes 3 Place the fan spigot through the hole in the glass from the inside with...

Page 6: ...ATION 1 Remove the fan grille The controller is factory set at 15 minutes approx The overrun time period can be adjusted from approximately 3 30 minutes by altering the adjuster on the control PCB 2 T...

Page 7: ...ill return to the auto humidity sensing mode once the pullcord is switched into the off position The LED indicator light will only activate if the PULLCORD is in the ON position LED INDICATOR LIGHT OP...

Page 8: ...LP XP LHTP XHTP if the Timer is not used Fig 1 N L 1 Phase Supply 220 240V 50Hz FUSE Switched Fused Spur 3A LS 12V 0V Controller Fan 12V D C SELV Supply N L LS LS N L 2 1 3 N LS 12V 0V Controller Fan...

Page 9: ...t 65 95 RH Overrun timer adjustment 1 30min SPEED SETTING The fan has two speed settings for different installation requirements High speed for ducted installations Replace jumper Normal speed for wal...

Page 10: ...ol Factor Control Typology CTRL Typology Control Factor CTRL 1 00 1 00 0 95 0 65 0 95 0 65 Control Typology Manual Control Manual Control Clock Control Local Demand Control Clock Control Local Demand...

Page 11: ...Notes...

Page 12: ...ective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Ha...