12) Re fit Electrical Cover with 2 screws indicated 
In  Fig 14. 
  

            

      

 

  
 
13) Re fit Cover Plate and tighten 2 screws Fig 15 &16. 
 Ensure Pull cord is engaged in Lower Slot  
 

                                                                    

 

          

      

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14) The Tempra unit is also fitted with a “manual summer setting” which allows the unit to be set to 
extract only, helping to prevent a dwelling becoming too warm in hot summer conditions. 
When first installed this shutter/vent should be 

open

. Fig.16 

To activate the summer setting it should be shut. 
 
15) Make good on outside wall with the wall 
Cover bezel provided, ensure the arrow on  
the bezel is at the top. 
Fix/seal to the wall with a suitable sealant. 
 
Apply sealant in outer groove  
on rear of bezel. 

Important:-

 Please ensure that 

you apply sufficient sealant to 
hold the bezel to the wall. (If the 
wall surface is not suitable for  
using sealant 2 screws can be  
located through the 2 bosses provided). 

Note:- 

Do not seal the bezel to the heat exchanger, this needs to be removed for cleaning at regular 

intervals.

        

  
       

                                                                      6 

Engage  
Pullcord in 
slot 

Fig.14 

Fig.15 Fig.16 

Fig.17 

Ensure this vent is 

open 

when installed to activate 
the heat recovery function 

Summary of Contents for Lo-Carbon Tempra SELV HTP

Page 1: ...ell LT 444370 Humidistat Timer Pullcord HTP 403837 Humidistat Timer Pullcord Long cell LHTP PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon SELV Tem...

Page 2: ...NGE SINCE THE FANS ARE SPECIALLY DESIGNED TO WORK ON 24v DC AND ARE NOT COMPATIBLE WITH OTHER VENT AXIA CONTROLLERS DO NOT CONNECT MORE THAN ONE FAN TO THE CONTROLLER F The controller must not be inst...

Page 3: ...n overrun timer and optional 3 minute delay on timer or internal humidistat adjustable 60 90 RH SELV Controller The controller can be installed surface or recess mounted using the supplied surface mou...

Page 4: ...Door Fig 6 6 Feed flexible LV cable from PSU through one of the rear entry points or the side entry point as required And then the door Fig 7 8 7 Fit Chassis to wall with 4 fixing screws carefully ali...

Page 5: ...Line up key on top of Heat Exchanger with slot in Chassis 10 Fit Heat Exchanger Retaining Clamp with the screws provided Fig 12 11 Close Door and connect 24V Supply as described in section B Wiring Ad...

Page 6: ...e shut 15 Make good on outside wall with the wall Cover bezel provided ensure the arrow on the bezel is at the top Fix seal to the wall with a suitable sealant Apply sealant in outer groove on rear of...

Page 7: ...r is suitable for connection to 220 240V 50Hz supply and 24V SELV to the fan The fan is a class ll double insulated product and MUST NOT be earthed 1 Select and follow the appropriate wiring diagram F...

Page 8: ...utes by altering the adjuster on the control PCB 2 To INCREASE the operating time use a small screwdriver to turn the TIMER adjuster CLOCKWISE 3 To REDUCE the operating time use a small screwdriver to...

Page 9: ...of dirt or other deposits 1 Remove 2 screws and lift off Cover Plate assembly Fig 21 22 2 Lift where indicated to engage hinges Fig 23 and open Door Fig 24 3 Remove Retaining Plate Carefully slide out...

Page 10: ...LT HTP LHTP 3 445892 SELV Cover assembly P LP T LT HTP LHTP 4 444377 SELV power supply unit P LP T LT HTP LHTP 5 445889 Pullcord PCB P LP only 6 445890 Timer PCB T LT only 7 445891 HTP PCB HTP LHTP o...

Page 11: ...0 0 70 Control Factor Control Typology CTRL Typology Control Factor CTRL 1 00 1 00 0 95 0 95 0 65 0 65 Control Typology Manual Control Manual Control Clock Control Clock Control Local Demand Control L...

Page 12: ...ective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Ha...