12) Re fit Electrical Cover with 2 screws indicated
In Fig 14.
13) Re fit Cover Plate and tighten 2 screws Fig 15 &16.
Ensure Pull cord is engaged in Lower Slot
14) The Tempra unit is also fitted with a “manual summer setting” which allows the unit to be set to
extract only, helping to prevent a dwelling becoming too warm in hot summer conditions.
When first installed this shutter/vent should be
open
. Fig.16
To activate the summer setting it should be shut.
15) Make good on outside wall with the wall
Cover bezel provided, ensure the arrow on
the bezel is at the top.
Fix/seal to the wall with a suitable sealant.
Apply sealant in outer groove
on rear of bezel.
Important:-
Please ensure that
you apply sufficient sealant to
hold the bezel to the wall. (If the
wall surface is not suitable for
using sealant 2 screws can be
located through the 2 bosses provided).
Note:-
Do not seal the bezel to the heat exchanger, this needs to be removed for cleaning at regular
intervals.
6
Engage
Pullcord in
slot
Fig.14
Fig.15 Fig.16
Fig.17
Ensure this vent is
open
when installed to activate
the heat recovery function