PRODUCT FICHE
For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014)
11
Name:
Vent
‐
Axia
Vent
‐
Axia
Vent
‐
Axia
Vent
‐
Axia
Vent
‐
Axia
Vent
‐
Axia
Model
ID
(Stock
Ref.)
:
Lo
‐
Carbon
Tempra
SELV
P
‐
444368
Lo
‐
Carbon
Tempra
SELV
LP
‐
403833
Lo
‐
Carbon
Tempra
SELV
T
‐
444369
Lo
‐
Carbon
Tempra
SELV
LT
‐
403835
Lo
‐
Carbon
Tempra
SELV
HTP
‐
444370
Lo
‐
Carbon
Tempra
SELV
LHTP
‐
403837
SEC
Class
E
E
E
E
B
B
SEC
Value
('Average')
41.30
41.30
41.68
41.68
43.99
43.99
SEC
Value
('Warm')
18.67
18.67
18.85
18.85
19.89
19.89
SEC
Value
('Cold')
80.79
80.79
81.54
81.54
86.06
86.06
Label
Required?
(Yes/No=Out
of
scope)
No
No
No
No
No
No
Declared
as:
RVU
or
NRVU/UVU
or
BVU
RVU
‐
BVU
RVU
‐
BVU
RVU
‐
BVU
RVU
‐
BVU
RVU
‐
BVU
RVU
‐
BVU
Speed
Drive
Multi
‐
Speed
Multi
‐
Speed
Multi
‐
Speed
Multi
‐
Speed
Multi
‐
Speed
Multi
‐
Speed
Type
HRS
(Recuperative,
Regenerative,
None)
None
None
None
None
None
None
Thermal
Eff:
[
(%),
NA(if
none)]
N/A
N/A
N/A
N/A
N/A
N/A
Max.
Flow
Rate
(m3/h)
54.00
54.00
54.00
54.00
54.00
54.00
Max.
Power
Input
(W):
(@Max.Flow
Rate)
26.60
26.60
26.60
26.60
26.60
26.60
LWA:
Sound
Power
Level
(dB)
53.52
53.52
53.52
53.52
53.52
53.52
Ref.
Flow
Rate
(m3/s)
0.01
0.01
0.01
0.01
0.01
0.01
Ref.
Pressure
Diff.
(Pa)
N/A
N/A
N/A
N/A
N/A
N/A
SPI
[W/(m3/h)]
0.70
0.70
0.70
0.70
0.70
0.70
Control
Factor
&
Control
Typology:
(CTRL/
Typology)
Control
Factor;
CTRL
1.00
1.00
0.95
0.95
0.65
0.65
Control
Typology
Manual
Control
Manual
Control
Clock
Control
Clock
Control
Local
Demand
Control
Local
Demand
Control
Declared:
‐
Max
Internal
&
External
Leakage
Rates(%)
for
BVUs
or
carry
over
(for
regenerative
heat
exchangers
only),
‐
&Ext.
Leakage
Rates
(%)
for
Ducted
UVUs;
N/A
N/A
N/A
N/A
N/A
N/A
Mixing
Rate
of
Non
‐
Ducted
BVUs
not
intended
to
be
equipped
with
one
duct
connection
on
either
supply
or
extract
air
side;
N/A
N/A
N/A
N/A
N/A
N/A
Position
and
description
of
visual
filter
warning
for
RVUs
intended
for
use
with
filters,
including
text
pointing
out
the
importance
of
regular
filter
changes
for
performance
and
energy
efficiency
of
the
unit
N/A
N/A
N/A
N/A
N/A
N/A
For
UVUs
(Instructions
Install
Regulated
Supply/Extract
Grilles
Façade)
In
F&W
In
F&W
In
F&W
In
F&W
In
F&W
In
F&W
Internet
Address
(for
Disassembly
Instructions)
www.vent
‐
axia.com
www.vent
‐
axia.com
www.vent
‐
axia.com
www.vent
‐
axia.com
www.vent
‐
axia.com
www.vent
‐
axia.com
Sensitivity
p.
Var20/
‐
20
Pa:
(for
Non
‐
Ducted
Vus)
N/A
N/A
N/A
N/A
N/A
N/A
Air
Tightness
‐
ID/OD
‐
(m3/h)
(for
Non
‐
Ducted
Vus)
N/A
N/A
N/A
N/A
N/A
N/A
Annual
Electricity
Consumption:
AEC
(kWh/a)
10.15
10.15
9.43
9.43
5.53
5.53
Annual
Heating
Saved:
AHS
(kWh/a)
AHS:
Average
41.30
41.30
41.68
41.68
43.99
43.99
AHS:
Warm
18.67
18.67
18.85
18.85
19.89
19.89
AHS:
Cold
80.79
80.79
81.54
81.54
86.06
86.06